Allen-Bradley 1770-M10 Assembly And Installation Manual page 24

Mass storage systems
Table of Contents

Advertisement

Figure 1.10
How to Connect the Twinaxial Cable to the 1770 M11 System
SERIAL CHANNEL J22
1
e.
loosen three consecutive screws to one channel (either the IN or
OUT channel) of the 1770-M11 system
f.
wrap the blue wire around the screw, labeled: 1; secure the screw
g.
wrap the shield drain wire around the screw, labeled: SHIELD;
secure the screw
h.
wrap the clear wire around the screw, labeled: 2; secure the screw
4.
Select the communication rate by sliding the BAUD RATE switch to the
correct selection. (Refer to chapter 4 page 4-5.)
5.
Plug the power cable into the power outlet.
If you need additional storage, you can connect up to three 1770-M10 systems
by performing these steps (Figure 1.11):
Chapter 3
Installing Your Mass Storage System
SH
2
1
SH
2
IN
OUT
11966
3 9