Chapter 3
Installing Your Mass Storage System
3 8
Figure 1.9
How to Connect the Twinaxial Cable to the Peripheral Communication Module
Line 1
Remote
Shield
Channel 1
Line 2
Line 1
Remote
Channel 2
Shield
Line 2
1770 CD Twinaxial Cable
Connect this end to the 1770 M11 Mass Storage System
a.
loosen three consecutive screws to one channel of the peripheral
communication module
b.
wrap the blue wire around the screw, labeled: LINE 1; secure the
screw
c.
wrap the shield drain wire around the screw, labeled: SHIELD;
secure the screw
d.
wrap the clear wire around the screw, labeled: LINE 2; secure the
screw
3.
Connect the other end to the 1770-M11 system at J22 (Figure 1.10). There
are 6 terminals which make up the serial channel port. Use three
consecutive screws when connecting the twinaxial cable to the peripheral
communication module:
Blue
Shield
Drain
Clear
Line 1
Remote
Shield
Channel 1
Line 2
Line 1
Remote
Shield
Channel 2
Line 2
1770 XT
Terminator
11965