Allen-Bradley 1770-M10 Assembly And Installation Manual page 10

Mass storage systems
Table of Contents

Advertisement

Chapter 2
Hardware Features of the Mass Storage
Systems
2 4
Restart Indicator (System Fault)
This LED labeled RESTART lights red when either:
the system cannot successfully start from the micro–floppy or Winchester
there is an internal fault detected on the Disk Memory Interface Module
(DMIM)
Or when one of the following conditions occurs:
download fault
Random Access Memory (RAM) parity error
system fault
hardware malfunction
module fault
Off indicates normal operation.
Restart Pushbutton
When you press this red pushbutton labeled RESTART, it:
causes the DMIM to load the 1770–M11 operating system program from the
micro–floppy; if there is not micro–floppy, the DMIM loads the operating
system from the Winchester disk drive
performs a power–up diagnostic check
Eject Pushbutton
Press the black eject pushbutton to release the micro–floppy from the access
slot. Then, remove the micro–floppy and store it in a vertical position inside the
original box.
We describe the care and use of micro–floppies in appendix A.

Advertisement

Table of Contents
loading

This manual is also suitable for:

1770-m111770-m12

Table of Contents