Connect To The Relay Ports; Add Ir Receiver Capabilities To Remote Locations - Control 4 Media Controller Installation And User Manual

Media controller
Table of Contents

Advertisement

Figure 2-6.
Connect Contact for Self Powered Voltage Source Device
12V
SIG
Signal
Input

Connect to the Relay Ports

The Media Controller provides one relay port as a subset of
the pluggable terminal block provided.
For most applications, attach one wire to the common
terminal and the other to the normally open terminal.
The relay switches close when the relay is activated.
The Media Controller can support applications that require a
normally closed contact.

Add IR Receiver Capabilities to Remote Locations

To add an IR-controlled receiver from a remote location to
your Media Controller:
1.
2.
3.
GND
Return
Path
Place your IR-controlled receiver at the remote
location needed.
Run the wires from the remotely located IR-controlled
receivers to the back of the Media Controller.
Connect the IR-controlled receiver wires (generally
power, signal, and ground) to one of the Media
Controller IR In connectors (pluggable terminal block
connectors).