Beeper Definitions - Symbol LS3478-FZ Reference Manual

Table of Contents

Advertisement

2-4
Symbol LS3478 Product Reference Guide

Beeper Definitions

The scanner emits different beeper sequences and patterns to indicate its status.
both normal scanning and while programming the scanner.
Beeper Sequence
Standard Use
Short low-short medium-short high beeps
One short high beep
Four long low beeps
Long low-high beeps
Four short high beeps
Long low-high-low-high beeps
Five long low beeps
Low-high-low beeps
Short high-short high-short low-short low beeps
Cordless Scanner Connection
Short low-short high beeps
Short high-short low beeps
Parameter Menu Scanning
Short high beep
Long low-long high beeps
Short high-short low beeps
Short high-short low-short high-short low beeps
ADF Programming Normal Data Entry
High-low beeps
Low-low beeps
High-high beeps
High-low-high-low beeps
High-low-low beeps
Low beep
Low-high-high beeps
Short low-short high-short low-short high beeps
ADF Programming Error Indications
Low-high-low-high beeps
Table 2-1. Standard Beeper Definitions
Power up.
A bar code symbol was decoded (if decode beeper is enabled).
A communication error occurred while transmitting a scanned symbol to a host. The data is ignored.
This occurs if the scanner is not properly configured or if the scanner has disconnected from the cradle.
Attempt to pair with the cradle was unsuccessful. Ensure that the cradle has power; if not, cycle power
to the cradle and re-attempt the pairing.
Low battery indication.
Attempt to pair with a cradle that is already paired with the maximum number of scanners.
Conversion or format error.
ADF transmit error.
Radio failure.
The scanner has connected to the cradle after scanning a pairing bar code or automatically after a
disconnect.
The scanner disconnected from the cradle either because the scanner moved out of range of the
cradle, the USB host suspended the cradle, or cradle power was interrupted.
Correct entry scanned or correct menu sequence performed.
Input error; incorrect bar code, programming sequence or 'Cancel' scanned. Scanner remains in ADF
program mode.
Keyboard parameter selected. Enter value using numeric bar codes.
Successful program exit with change in the parameter setting.
Enter another digit. Add leading zeros to the front if necessary.
Enter another alphabetic character or scan the End of Message bar code.
Enter another criterion or action, or scan the Save Rule bar code.
Rule saved. Rule entry mode exited.
All criteria or actions cleared for current rule, continue entering rule.
Delete last saved rule. The current rule is left intact.
All rules have been deleted.
Out of host ADF parameter storage space. Scan
Out of rule memory. Erase some existing rules, then try to save rule again. (It is not necessary to re-
enter the current rule.)
Table 2-1
defines beep sequences that occur during
Indication
Set Default Parameter on page
4-5.