LS 3203ER Product Reference Guide: Parameter Menus Set Default Parameters Refer to the Default Table on page 2-28. To set defaults for any or all host types, scan the appropriate bar code below. Then select a specific host interface on the next page. SET RS-232C DEFAULTS SET WAND DEFAULTS SET SYNAPSE DEFAULTS...
LS 3203ER Product Reference Guide: Parameter Menus Host Interface Select To select a host interface, scan the appropriate bar code below. SET RS-232C HOST SET WAND HOST SET SYNAPSE HOST...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Fixed Format Options Select fixed format options for the terminals listed below. SET NIXDORF RS-232C FORMATS SET FUJITSU RS-232C FORMATS SET ICL RS-232C FORMATS...
Page 6
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Code Type Add or delete specific code types by scanning the appropriate bar code(s). ADD CODE 39 DELETE CODE 39 DELETE UPC-A ADD UPC-A DELETE UPC-E ADD UPC-E DELETE CODABAR ADD CODABAR...
Page 7
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Code Type ADD EAN-8 DELETE EAN-8 DELETE EAN-13 ADD EAN-13 DELETE I 2 OF 5 ADD I 2 OF 5 ADD D 2 OF 5 DELETE D 2 OF 5...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Code 2 of 5 Lengths To set the lengths for each code type: 1. Scan the desired option. 2. Scan two bar codes on page 3-10 for each desired length. For example, for a length of “12”, scan “1”...
Page 10
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Code 2 of 5 Lengths CANCEL 3-10...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Decode Options DO NOT TRANSMIT UPC-A TRANSMIT UPC-A CHECK DIGIT CHECK DIGIT DO NOT TRANSMIT UPC-E TRANSMIT UPC-E CHECK DIGIT CHECK DIGIT DO NOT CONVERT CONVERT UPC-E TO UPC-A UPC-E TO UPC-A 3-11...
Page 12
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Decode Options DECODE UPC/EAN IGNORE UPC/EAN WITH SUPPLEMENTALS WITH SUPPLEMENTALS ENABLE EAN ZERO EXTEND DISABLE EAN ZERO EXTEND TRANSMIT “NO DECODE” DO NOT TRANSMIT MESSAGE “NO DECODE” MESSAGE 3-12...
Page 13
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Decode Options ENABLE CLSI EDITING DISABLE CLSI EDITING ENABLE NOTIS EDITING DISABLE NOTIS EDITING ENABLE CODE 39 DISABLE CODE 39 FULL ASCII FULL ASCII VERIFTY CODE 39 DO NOT VERIFY CODE 39 CHECK DIGIT CHECK DIGIT 3-13...
Page 14
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Decode Options ITF-14/EAN-13 CONVERSION ITF-14/EAN-13 CONVERSION DISABLED ENABLED DO NOT BEEP AFTER GOOD DECODE BEEP AFTER GOOD DECODE DO NOT BUFFER CODE 39 BUFFER CODE 39 3-14...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host UPC-A Preamble Select one option for UPC-A preamble by scanning the appropriate bar code. NONE SYSTEM CHARACTER SYSTEM CHARACTER & COUNTRY CODE 3-17...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host UPC-E Preamble Select one option for UPC-E preamble by scanning the appropriate bar code. NONE SYSTEM CHARACTER SYSTEM CHARACTER & COUNTRY CODE 3-18...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Intercharacter Delay To set a host communications intercharacter delay: 1. Scan the INTERCHARACTER DELAY bar code below. 2. Scan two bar codes on the next page which represent the desired delay (from 00 to 99 msec).
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Data Transmission Formats Scan the option you wish to set. DATA AS IS <PREFIX> <DATA> <DATA> <SUFFIX> <PREFIX> <DATA> <SUFFIX> 3-21...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Prefix/Suffix Values To set a PREFIX/SUFFIX value: 1. Scan the option bar code you wish to set. 2. Scan four bar codes on the next page which correspond to the ASCII value or keystroke you wish to assign.
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Transmit Code ID Character Select whether to enable or disable this parameter. TRANSMIT CODE ID CHARACTER DO NOT TRANSMIT CODE ID CHARACTER 3-24...
Page 25
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Transmit AIM ID Character Select whether to enable or disable this parameter. TRANSMIT AIM ID CHARACTER DO NOT TRANSMIT AIM ID CHARACTER 3-25...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Laser On Time-out To select a laser on time-out, scan the bar code below or on the next page corresponding to the desired time. 0.5 SECONDS 1.0 SECONDS 2.0 SECONDS 1.5 SECONDS 3.0 SECONDS 2.5 SECONDS 3-26...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Baud Rate Set the baud rate for RS-232C transmission. 4800 1200 9600 2400 19200 3-28...
Page 29
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Parity Set the type of parity for RS-232C transmission. EVEN MARK SPACE NONE 3-29...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Beep on BEL Select whether or not enable this parameter. BEEP ON BEL DO NOT BEEP ON BEL 3-30...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Software Handshaking Select the type of RS-232C software handshaking protocol. NONE ACK/NAK ENQ ONLY ACK/NAK with ENQ XON/XOFF 3-32...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Stop Bit Select Select the desired number of stop bits for RS-232C communications. 1 STOP BIT 2 STOP BITS 3-33...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host ASCII Data Format Select either 7-bit or 8-bit ASCII format for RS-232C communications. 7-BIT 8-BIT 3-34...
LS 3203ER Product Reference Guide: Parameter Menus RS-232 Host Power Mode Select whether the laser remains on continuously, or turns off after a decode attempt (Low Power). CONTINUOUS ON LOW POWER 3-35...
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Interface Select the appropriate host by scanning one of the bar codes below. SYMBOLLINK CONTROLLER SYMBOL PORTABLE TERMINAL NORAND TERMINAL 3-36...
Page 37
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Code Type Add or delete specific code types by scanning the appropriate bar code(s). ADD CODE 39 DELETE CODE 39 ADD UPC-A DELETE UPC-A DELETE UPC-E ADD UPC-E DELETE CODABAR ADD CODABAR 3-37...
Page 38
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Code Type ADD EAN-8 DELETE EAN-8 DELETE EAN-13 ADD EAN-13 DELETE I 2 OF 5 ADD I 2 OF 5 DELETE D 2 OF 5 ADD D 2 OF 5 3-38...
Page 40
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Code 2 of 5 Lengths To set the lengths for each code type: 1. Scan the desired option. 2. Scan two bar codes on page 3-41 for each desired length. For example, for a length of “12”, scan “1”...
Page 41
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Code 2 of 5 Lengths CANCEL 3-41...
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Decode Options DECODE UPC/EAN IGNORE UPC/EAN WITH SUPPLEMENTALS WITH SUPPLEMENTALS DO NOT BEEP AFTER GOOD DECODE BEEP AFTER GOOD DECODE ENABLE 1 MSI/Plessey ENABLE 2 MSI/Plessey CHECK DIGITS CHECK DIGIT 3-42...
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Laser On Time-out To select a laser on time-out, scan the bar code below or on the next page corresponding to the desired time. 0.5 SECONDS 1.0 SECONDS 2.0 SECONDS 1.5 SECONDS 3.0 SECONDS 2.5 SECONDS 3-44...
Page 46
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Power Mode Select whether the laser remains on continuously, or turns off after a decode attempt (Low Power). CONTINUOUS ON LOW POWER 3-46...
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Wand Emulator Bar Output Select the option that matches your host system. BAR HIGH BAR LOW 3-47...
LS 3203ER Product Reference Guide: Parameter Menus Wand Host Convert All to Code 39 Select whether or not to convert the decoded output to Code 39. CONVERT ALL TO CODE 39 DO NOT CONVERT ALL TO CODE 39 3-50...
Page 51
LS 3203ER Product Reference Guide: Parameter Menus Synapse Code Type Add or delete specific code types by scanning the appropriate bar code(s). ADD CODE 39 DELETE CODE 39 ADD UPC-A DELETE UPC-A ADD UPC-E DELETE UPC-E ADD CODABAR DELETE CODABAR 3-51...
Page 52
LS 3203ER Product Reference Guide: Parameter Menus Synapse Code Type ADD EAN-8 DELETE EAN-8 DELETE EAN-13 ADD EAN-13 DELETE I 2 OF 5 ADD I 2 OF 5 DELETE D 2 OF 5 ADD D 2 OF 5 3-52...
LS 3203ER Product Reference Guide: Parameter Menus Synapse Code 2 of 5 Lengths To set the lengths for each code type: 1. Scan the desired option. 2. Scan two bar codes on page 3-55 for each desired length. For example, for a length of “12”, scan “1”...
Page 55
LS 3203ER Product Reference Guide: Parameter Menus Synapse Code 2 of 5 Lengths CANCEL 3-55...
LS 3203ER Product Reference Guide: Parameter Menus Synapse Decode Options TRANSMIT UPC-A DO NOT CHECK DIGIT TRANSMIT UPC-A CHECK DIGIT TRANSMIT UPC-E DO NOT CHECK DIGIT TRANSMIT UPC-E CHECK DIGIT CONVERT DO NOT UPC-E TO UPC-A CONVERT UPC-E TO UPC-A 3-56...
Page 57
LS 3203ER Product Reference Guide: Parameter Menus Synapse Decode Options DECODE UPC/EAN IGNORE UPC/EAN WITH SUPPLEMENTALS WITH SUPPLEMENTALS ENABLE EAN ZERO EXTEND DISABLE EAN ZERO EXTEND TRANSMIT “NO DECODE” DO NOT TRANSMIT MESSAGE “NO DECODE” MESSAGE 3-57...
Page 58
LS 3203ER Product Reference Guide: Parameter Menus Synapse Decode Options ENABLE CLSI EDITING DISABLE CLSI EDITING ENABLE NOTIS EDITING DISABLE NOTIS EDITING ENABLE CODE 39 DISABLE CODE 39 FULL ASCII FULL ASCII VERIFTY CODE 39 DO NOT VERIFY CODE 39 CHECK DIGIT CHECK DIGIT 3-58...
Page 59
LS 3203ER Product Reference Guide: Parameter Menus Synapse Decode Options ITF-14/EAN-13 CONVERSION ITF-14/EAN-13 CONVERSION DISABLED ENABLED DO NOT BEEP AFTER GOOD DECODE BEEP AFTER GOOD DECODE BUFFER CODE 39 DO NOT BUFFER CODE 39 3-59...
Page 61
LS 3203ER Product Reference Guide: Parameter Menus Synapse Decode Options ENABLE 1 MSI/Plessey ENABLE 2 MSI/Plessey CHECK DIGIT CHECK DIGITS MSI 2 CHECK DIGITS MSI 2 CHECK DIGITS MOD 10 - MOD 10 MOD 11 - MOD 10 ENABLE CODABAR DISABLE CODABAR DECODE REDUNDANCY DECODE REDUNDANCY...
Page 62
LS 3203ER Product Reference Guide: Parameter Menus Synapse UPC-A Preamble Select one option for UPC-A preamble by scanning the appropriate bar code. NONE SYSTEM CHARACTER SYSTEM CHARACTER & COUNTRY CODE 3-62...
Page 63
LS 3203ER Product Reference Guide: Parameter Menus Synapse UPC-E Preamble Select one option for UPC-E preamble by scanning the appropriate bar code. NONE SYSTEM CHARACTER SYSTEM CHARACTER & COUNTRY CODE 3-63...
Page 64
LS 3203ER Product Reference Guide: Parameter Menus Synapse Data Transmission Formats Scan the option you wish to set. DATA AS IS <PREFIX> <DATA> <DATA> <SUFFIX> <PREFIX> <DATA> <SUFFIX> 3-64...
Page 65
LS 3203ER Product Reference Guide: Parameter Menus Synapse Prefix/Suffix Values To set a PREFIX/SUFFIX value: 1. Scan the option bar code you wish to set. 2. Scan three bar codes on the next page which correspond to the ASCII value or keystroke you wish to assign.
Page 67
LS 3203ER Product Reference Guide: Parameter Menus Synapse Transmit Code ID Character Select whether to enable or disable this parameter. TRANSMIT CODE ID CHARACTER DO NOT TRANSMIT CODE ID CHARACTER 3-67...
Page 68
LS 3203ER Product Reference Guide: Parameter Menus Synapse Transmit AIM ID Character Select whether to enable or disable this parameter. TRANSMIT AIM ID CHARACTER DO NOT TRANSMIT AIM ID CHARACTER 3-68...
LS 3203ER Product Reference Guide: Parameter Menus Synapse Laser On Time-out To select a laser on time-out, scan the bar code below or on the next page corresponding to the desired time. 0.5 SECONDS 1.0 SECONDS 2.0 SECONDS 1.5 SECONDS 3.0 SECONDS 2.5 SECONDS 3-69...
LS 3203ER Product Reference Guide: Parameter Menus Synapse Power Mode Select whether the laser remains on continuously, or turns off after a decode attempt (Low Power). CONTINUOUS ON LOW POWER 3-71...
Need help?
Do you have a question about the LS-3203ER and is the answer not in the manual?
Questions and answers