Symbol LS3478-FZ Reference Manual page 102

Table of Contents

Advertisement

Hardware Handshaking (continued)
RTS/CTS Option 1
When RTS/CTS Option 1 is selected, the scanner asserts RTS before transmitting and ignores the state of CTS. The scanner de-
asserts RTS when the transmission is complete.
RTS/CTS Option 2
When Option 2 is selected, RTS is always high or low (user-programmed logic level). However, the scanner waits for CTS to be
asserted before transmitting data. If CTS is not asserted within Host Serial Response Time-out (default), the scanner issues an error
indication and discards the data.
RTS/CTS Option 3
When Option 3 is selected, the scanner asserts RTS prior to any data transmission, regardless of the state of CTS. The scanner waits
up to Host Serial Response Time-out (default) for CTS to be asserted. If CTS is not asserted during this time, the scanner issues an
error indication and discards the data. The scanner de-asserts RTS when transmission is complete.
RTS/CTS Option 1
RTS/CTS Option 2
RTS/CTS Option 3
RS-232 Interface 6-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls3478-er

Table of Contents