A/C Unit Construction/Operation; Air Mix Door Operation - Mazda RX-8 2004 Service Highlights

Mazda rx-8 2004
Hide thumbs Also See for RX-8 2004:
Table of Contents

Advertisement

A/C UNIT CONSTRUCTION/OPERATION

Construction
• An A/C unit with integrated cooling and heater units has been adopted.
— Evaporator
— Heater core
— Expansion valve
— Air mix door
— Airflow mode door
— Evaporator temperature sensor
— Resistor (blower motor)
— Air mix actuator
— Airflow mode actuator
— A/C amplifier

Air Mix Door Operation

• The air mix door, installed in the A/C unit, controls HOT or COLD positions, depending on the position of the
temperature control dial. As a result, the airflow distribution changes, and the airflow temperature is controlled.
EVAPORATOR
AIR MIX
DOOR
07–11–4
BASIC SYSTEM
HEATER CORE
[COLD]
EVAPORATOR
TEMPERATURE
EVAPORATOR
SENSOR
AIRFLOW
MODE DOOR
AIRFLOW
MODE
ACTUATOR
A/C AMPLIFIER
AIRFLOW
MODE MAIN LINK
AIR MIX ACTUATOR
AIR MIX DOOR
CHU071161130S01
EXPANSION VALVE
RESISTOR
(BLOWER
MOTOR)
AIR MIX
DOOR
AIRFLOW
MODE DOOR
HEATER CORE
CHU0711S008
[HOT]
CHU0711S009

Advertisement