DLC-2 CONSTRUCTION
• A DLC-2 connector conforming to ISO (International Organization for Standardization) standards has been
added.
• Shape and terminal arrangement as stipulated by the ISO 15031-3 (SAE J1962) international standard has
been adopted for this connector. The connector has a 16-pin construction that includes the CAN_H, CAN_L,
GND1, GND2 and B+ terminals.
Terminal
CAN _L
CAN_H
GND1
GND2
B+
End Of Sie
ON-BOARD DIAGNOSTIC
DLC-2
B+
CAN_L
CAN_H GND2
Serial communication terminal (Lo)
Serial communication terminal (Hi)
Body GND terminal
Serial communication GND terminal
Battery power supply terminal
GND1
Function
CHU060201038S06
CHU0602S002
06–02