8.7
Setting the priority
Functionality
The priority determines the sequence in which the storage tanks are loaded (only for
systems with more than 1 storage tank). If the higher priority storage tank (first-priority
storage tank) cannot be loaded because the collector temperature is too low then the
lower priority storage tank (second-priority storage tank) is loaded
values can be selected:
-1-: Only storage tank 1 is loaded.
-2-: Only storage tank 2 is loaded.
1-2: Storage tank 1 is the first-priority storage tank.
2-1: Storage tank 2 is the first-priority storage tank.
1)
Every 30 minutes, the controller checks to see if the first-priority storage tank can be loaded.
Due to the warming of the collector array this check can take several minutes. On the basis of
the heating process, the controller predicts whether it is possible to load the first-priority storage
tank in a foreseeable period of time.
Operation
P
√
rio flashes.
1. Press SET. The current value flashes.
2. - Press to change the priority. The system graphics change accordingly.
3. Press SET. The change is adopted.
8.8
Resetting to factory defaults
√
flashes, RESEt is displayed (RE and SEt alternately).
1. Press and hold SET for 5 seconds.
2. After a brief progress display, ok is displayed and the reset is finished.
3. Continue as described in Section 4, p. 13.
742.892 | 11.50