Calling up the settings menu and selecting a menu entry

Automatic or Off mode is selected.
1. Press and hold SET for two seconds. The settings menu is displayed, menu entry
flashes.
2. Press  to select a different menu entry.
3. Change the settings as described in the following sections.
8.3

Setting the time

flashes.
1. Press SET. The hours display flashes.
2. Press  to change the hour.
3. Press SET. The minutes flash.
4. Press  to change the minute.
5. Press SET. The change is adopted.
8.4

Setting the system

Note
The systems are described in Section 3.4, p. 10.
S
yst
1. Press SET. The number of the current system flashes.
2. Press  to select another system.
3. Press SET. The change is adopted.
8.5

Setting the functions

F
unc
X Continue as described in Section 9, p. 28.
8.6

Setting the parameters

Note
Details on the parameters are provided in Section 10, p. 43.
P
ara flashes.
1. Press SET. P:01 (parameter number) flashes.
2. Press  to display a different parameter.
3. Press SET. The value of the parameter is displayed, associated components flash in
the system graphics.
4. Press SET. The parameter value flashes.
5. Press  to change the value.
6. Press SET to adopt the change.
7. Press ESC. The parameter number is displayed (flashing).
8. If necessary, repeat steps 2 – 7.
26
flashes.
flashes.
742.892 | 11.50

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Temperature differential controller and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Solar

Table of Contents

Save PDF