Heat pump split single service 3 phase
Line
Function
Domestic hot water (DHW) (Only with the DHW kit option)
5020
S
Flow setpoint boost
5024
S
Switching diff
5030
S
Charging time limitation
5060
S
Electrical resistance regime
5061
S
Electrical resistance release
Installation configuration
5700
I
Pre-setting
This control enables you to choose one of the 8 pre-selected installation configurations. The hydraulic layouts for the
various configurations are detailed in the section : "Installation Configurations".
- Pre-setting 1 : 1 heating circuit
- Pre-setting 2 : 1 heating circuit and DHW tank.
- Pre-setting 3 : 2 heating circuits.
- Pre-setting 4 : 2 heating circuits and DHW tank.
- Pre-setting 5 : Boiler connection and 1 heating circuit.
- Pre-setting 6 : Boiler connection and 2 heating circuits
- Pre-setting 7 : Boiler connection, 1 heating circuit and DHW tank.
- Pre-setting 8 : Boiler connection, 2 heating circuits and DHW tank.
- Pre-setting 9 to 12 : Do not use for heat pump single service. Reserved only for heat pump 2 services.
5711
S
Cooling circuit 1
5870
S
Combi storage tank
5987
S
Cont type input EX4
5989
S
Cont type input EX5
6046
I
Function input H2
1 - Operating mode change HCs + DHW
2 - Operating mode change HCs
3 - Operating mode change HC1
4 - Operating mode change HC2
6 - Error/alarm message
9 - Dew point monitoring
16 - Swimming pool release
6047
I
Contact type H2
6048
S
Function value contact H2
6100
S
Readjustm outside sensor
S
6120
Frost protection plant
6205
S
Reset to default parameters
6220
S
Software version (RVS)
Error
6711
U
Reset HP
6740
S
Flow temp HC1 alarm
6741
S
Flow temp HC2 alarm
6745
S
DHW charging alarm
6746
S
Flow temp cooling 1 alarm
Installation and operating manual "1364 - EN"
Setting range
or display
0... 30 °C
0... 20 °C
10... 600 min
Substitute, Summer, Always,
Cooling mode
24h / day, Release of DHW,
Programme 4 / DHW
1,2,3,... 12
Off, System with 4 tubes,
System with 2 tubes
No, Yes
Normally-closed contact (NC)
Normally-opened contact (NO)
Normally-closed contact (NC)
Normally-opened contact (NO)
1... 16
NC - Normally-closed,
NO - Normally-opened
0... 130 °C
-3... 3 °C
On, Off
No, Yes
0... 99
No, Yes
--, 10... 240 min
--, 10... 240 min
--, 1... 48 h
--, 10... 240 min
Setting
Basic
increment
setting
1 °C
5 °C
1 °C
7 °C
10 min
90 min
Substitute
Release of
DHW
1
1
Off
No
NO
NC
1
9
NO
1 °C
45 °C
0,1 °C
0 °C
On
No
No
10 min
--
10 min
--
1 h
--
10 min
--
- 39 -