Fujitsu 112 Installation And Operating Manual page 34

Heat pump air/water split single service 3 phase
Hide thumbs Also See for 112:
Table of Contents

Advertisement

Heat pump split single service 3 phase
Line
Function
Time programme 5 / Cooling
If the installation is fitted with the cooling kit (Only with the cooling kit option).
600
U
Pre-selection (Day / Week)
Mon-Sun Mon-Fri Sat-Sun Monday Tuesday...
601
U
1
phase On (start)
st
602
U
1
phase Off (end)
st
603
U
2
phase On (start)
nd
604
U
2
phase Off (end)
nd
605
U
3
phase On (start)
rd
606
U
3
phase Off (end)
rd
616
U
Default values
Yes + OK : The Default values memorised in the regulator replace and cancel the customised heating programmes. Your
customised settings are therefore lost.
Holidays, heating circuit 1
641
U
Preselection
642
U
Start (Day / Month)
643
U
End (Day / Month)
U
648
Operating level (during the holidays)
Holidays, heating circuit 2
If the installation consists of 2 heating circuits (Only with the 2
651
U
Preselection
652
U
Start (Day / Month)
653
U
End (Day / Month)
658
U
Operating level (during the holidays)
Heating, circuit 1
710
U
Comfort heating setpoint
712
U
Reduced setpoint
714
U
Frost protection setpoint
716
S
Comfort setpoint max
720
I
Heating curve slope (See
721
I
Heating curve displacement
726
I
Heating curve adaption
730
I
Summer / Winter heating limits
When the average of the outdoor temperatures over the past 24 hours reaches 18°C, the regulator switches off the
heating (as an economy measure).
During summer mode, the display shows "Eco". This function is only active in automatic mode.
732
S
24-hour heating limit
This function enables you partially to offset the automatic summer / winter switchover during the intermediate seasons.
Increasing the value delays the switchover to summer regime.
Decreasing the value advances the switchover to summer regime.
This function is only active in automatic mode.
740
S
Flow temp setpoint min (for fan convectors)
- 34 -
figure
41).
(see §
3.3.2)
Setting range
or display
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
00:00... --:--
No, Yes
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection, Reduced
circuit kit option)
nd
Period 1 to 8
01.01... 31.12
01.01... 31.12
Frost protection, Reduced
from reduced setpoint to 35°C
from frost protection setpoint...
to comfort setpoint
from 4°C...
to reduced setpoint
20 °C... 35 °C
0,1... 4
-4,5 °C... 4,5 °C
Off, On
8 °C... 30 °C
-10 °C... 10 °C
8... 95 °C
Installation and operating manual "1364 - EN"
Setting
Basic
increment
setting
Mon-Sun
10 min
8:00
10 min
20:00
10 min
--:--
10 min
--:--
10 min
--:--
10 min
--:--
No
Period 1
1
1
Frost
protection
Period 1
1
1
Frost
protection
0,5 °C
20 °C
0,5 °C
18 °C
0,5 °C
8 °C
1 °C
28 °C
0,02
0,5
0,5 °C
0
Off
0,5 °C
18 °C
1 °C
-3 °C
1 °C
8 °C