Ferroli TEMPRA 30 Installation, Service And User Instructions Manual page 36

Copper wall-mounted system, gas fired boiler for central heating, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

7.11 Spark or fl ame detect electrode (fi g. 35)
• Isolate gas and electricity supply
• Remove outer case (two screws bottom rear
corners)
• Open room sealed compartment and
combustion chamber
• Identify electrode from fi g. 32
• Unplug electrical connection "A" from sensing
electrode
• Remove fi xing screw and remove fl ame detect
electrode
• Remove the two fi xing screw from spark
electrode plate and remove it.
7.12 Pump (fi g. 36)
Replacement of pump head
• Isolate electricity and fl ow and return pipes
• Remove casing (two screws bottom rear corners).
• Remove the two securing screws and lower control
panel
• Release pressure from boiler via pressure relief valve
• Unplug the pump lead "A" from the pump head
• Place a piece of cloth or other absorbent material over
the rear of the control panel to catch any drops of water
that may fall when the pump head is removed.
• Using a 4mm allen wrench undo the four allen screws
"B" in the pump head, lift away pump head from the
pump body
• fi t new head into pump body and secure with the allen
screws tightening evenly.
• Replace electrical connection.
Replacement of pump body (fi g. 36)
• Proceed as for removal of pump head
• Disconnect the expansion vessel connecting pipe "E"
from the rear of the pump body by removing the clip
from the left hand side
• Disconnect the boiler return pipe
• Disconnect the pump to heat exchanger connection by removing the clip "F"
• Unscrew the nut on bottom of pump
• Turn the pump body through 90°, pull the bottom forward and withdraw the pump body
• Reassemble in reverse order taking care to ensure the O-rings are in place and undamaged.
7.13 Removal of heat exchanger
• Isolate gas, water and electricity supplies
• Remove casing (2 screws bottom corners)
• Remove the two securing screws and lower control panel
• Drain heat exchanger for both CH + DHW
• Remove sealed compartment front panel
• Disconnect the overheat thermostat and central heating limit thermostat
• Remove the main burner, fan, fl ue hood and fl ow meter as described previously
• Remove the pump to heat exchanger fl ow connection and locknut
• Undo the domestic water outlet connection and locknut
• Lift out heat exchanger
• Re-assemble in reverse order
36
TEMPRA 30
Flame
detect
A
F
A
B
Spark
Fig. 35
E
Fig. 36