Wiring Diagram - Ferroli TEMPRA 30 Installation, Service And User Instructions Manual

Copper wall-mounted system, gas fired boiler for central heating, fan assisted, room sealed compartment, electronic flame ignition and control
Table of Contents

Advertisement

Tempra 30 "S" Plan
FERROLI
TEMPRA
APPLIANCE
Tempra 30 Junction Box
1
2
3
4
Switched live to appliance
PROGRAMMER
DHW ON
CH ON
NEUTRAL
LIVE
BROWN
CH
zone
valve
DHW
zone
valve
GREY
Pipework layout
A.A.V
D.H.W.
Zone Valve

Wiring diagram

5
6
7
8
Resistor
DO NOT REMOVE
1 2 3 4 5 6 7 8 9 10
BLUE
ORANGE
TEMPRA 30
C.H.
Zone Valve
IMPORTANT
It is necessary to provide 230v A/C switched supply
from external controls (ie motorised valve or room stat)
The supply must be connected to terminal 2 on appliance
connector block.
To ensure a passage of 6ltrs
per minute an Automatic
by-pass must be fitted.
(Building regulation part L)
N
E
L
230 Vac
fused at
3 amps
Room Thermostat
Cylinder Thermostat
Fig. 24b
Fig. 24a
25