Example of calculation for wall inlet/outlet
with 2 pipe system
maximum total fl ue length: 48 metres
7
6
5
4
3.04.3 Example of other installation with two pipe systems
Example of wall inlet/outlet
2 pipe application
18
TEMPRA 30
Attention:
REF. N° OF PIECES DESCRIPTION
2
1
3
1
2
3
4
5
6
7
Fig. 17
Fig. 18
Resistance of fl ue restrictor (if req.) is included
Remove the fl ue restrictor.
The fl ue and air pipes must have an inclination
downward equal to 3% from boiler to outside.
1
Air bend 80 mm R/D = 0,75
13
Horizontal air pipe
1
Air wall terminal
1
Air inlet closing fl ange
1
Flue bend 80 mm R/D = 0,75
12
Horizontal fl ue
1
Air wall terminal outlet fl ue
Example
of roof inlet/outlet
CODE
LENGTH OR
REDUCTION
1,5 m
13,0 m
2,0 m
2,5 m
24,0 m
5,0 m
TOTAL
48,0 m