Technical Data - STIEBEL ELTRON Hydro-Shark SH3-07 Installation Instructions Manual

3 modulating micro boilers, radiant floor heating applications
Hide thumbs Also See for Hydro-Shark SH3-07:
Table of Contents

Advertisement

PHONE:
800-355-4945

TECHNICAL DATA

"A" MODEL - 14 1/4 H X 7 7/8 W X 4 1/8 D - 1/2 PLUMBING FITTINGS
MODEL
SH3-07
SH3-10
"B" MODEL - 14 1/2 H X 16 5/8 W X 4 5/8 D - 3/4 PLUMBING FITTINGS
MODEL
KW
SH3-12
SH3-14
14.4
SH3-19
19.2
SH3-24
"C" MODEL - 14 1/2 H X 16 5/8 W X 4 5/8 D 3/4 PLUMBING FITTINGS
MODEL
KW
SH3-29
28.8
SH3-36
NOTE:
1. Boilers are considered a continuous load.
2. Copper conductors only.
SERVICE BULLETIN: Polarity matters on the Hydro-Shark Models with multiple circuits. On models
Sh3-14,19,24,29 and 36 the polarity of L1/L2 maters. If the installer places L1 on the left side of circuit
1, than L1 has to be placed on the left side of circuit 2 (SH3-14,19,24) and circuit 3 (SH3-29,36).
It does not matter if L1 or L2 is placed on the left or right side on the wireing block. It only
maters that all circuits are wired consistently, with L1 either always on the left or always on
the right. If the boiler will not run, reverse the L1 and L2 wires on one or two of the wiring
block to make the "polarity" consistent. The Factory is making changes to the interior wiring
so that the L1/L2 Polarity will not mater in the future. -May 14,2009
EMAL:
info@energyproducts.biz
KW
BTU
7.2
24,573
9.6
32,764
BTU
12
40,968
49,161
65,548
24
81,936
BTU
98,323
36
122,904
VOLTS
AMPS
240
30
240
40
VOLTS
AMPS
240
50
240
60
240
80
240
100
VOLTS
AMPS
240
120
240
150
10
WEB:
www.energyproducts.biz
BRKR
WT-LBS
(1)40
(1)50
BRKR
WT-LBS
(1)70
(2)40
(2)50
(2)70
BRKR
WT-LBS
(3)50
(3)70
5.9
5.9
17
20
20
20
24
24