FLUID CONNECTIONS

NOTE: EXCESSIVE HEAT FROM SOLDERING COPPER PIPES NEAR THE BOILER MAY CAUSE DAMAGE.
1. All plumbing work must comply with the national, state, local & any other applicable codes.
2. Make sure the radiant fl oor system has been purged & is free of fl oating debris.
3. The return side (inlet) is on the right side of the unit, the supply side (outlet) is on the
left of the unit.
4. A pressure & temprature relief valve should be installed on the hot water supply side
(outlet) of the unit.
5. The boiler is designed for a connection to copper tubing and/or PEX tubing. If soldering the
unit is necessary, please direct the fl ame away from the housing of the unit to avoid damage.
6. When all plumbing work is completed, check for leaks & take corrective action
before proceeding.
EMAL:
info@energyproducts.biz
SUPPLY OUTLET
RETURN INLET
6