Summary of Contents for STIEBEL ELTRON HydroShark 7
Page 1
» HydroShark 19 » HydroShark 24 » HydroShark 29 » HydroShark 36 HydroShark 7 - HydroShark 10: Conforms to ANSI/UL Std. 499 Certifi ed to CAN/CSA Std. E335-1 & E335-2-35 Conforme à la norme ANSI/UL Std. 499 Certifi é à la norme CAN/CSA Std. E335-1 & E335-2-35 HydroShark 12 - HydroShark 36: Conforms to ANSI/UL Std.
Page 2
Stiebel Eltron 800.805.5384 HydroShark Electric Boiler features advanced technology, impressive energy-saving performance, and a compact design. Exclusively manufactured by Models: Stiebel Eltron, a leader in heating technologies for the past 80 years. HydroShark 7 Featuring HydroShark 10 • Effi ciency: 100 % HydroShark 12 •...
IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OR OPERATION OF THESE BOILER, PLEASE CALL OUR TECHNICAL SERVICE LINE AT 800.805.5384. **Unless when used with Stiebel Eltron DHW Integrator Panels (Use HydroShark 29 or HydroShark 36 KW Boilers only with Combi Panel Systems, Size boilers accordingly) WWW.HYDRO-SHARK.COM...
Installation Manual CONGRATULATIONS Congratulations and thank you for choosing our micro boiler. Before use, we recommend that you read through this installation manual carefully. Keep this manual for future reference. If you need an additional manual, contact the manufacturer or your local distributor.
Save these instructions for future reference. Installer should leave these instructions with the consum- If you have any questions regarding the installation, use or operation of this micro boiler, or if you need any additional installation manuals call Stiebel Eltron at 800.805.5384 or visit us online at www. hydro-shark.com GENERAL •...
MOUNTING THE UNIT UNIT MUST BE INSTALLED IN A VERTICAL POSITION WITH THE WA- TER FITTINGS POINTING DOWNWARD. DO NOT INSTALL UNIT WHERE IT WOULD ROUTINELY BE SPLASHED WITH WATER OR ELECTRICAL SHOCK MAY RESULT. 1. Leave a minimum of 5” clearance on all sides for servicing. 2.
INSTALLATION ELECTRICAL CONNECTIONS WARNING: BEFORE BEGINNING ANY WORK ON THE ELECTRIC INSTAL- LATION, BE SURE THAT THE MAIN BREAKER PANEL SWITCHES ARE “OFF” TO AVOID ANY DANGER OF ELECTRIC SHOCK. ALL MOUNTING AND PLUMBING MUST BE COMPLETED BEFORE PROCEEDING WITH ELECTRICAL HOOK-UP.
4. A pressure & temperature relief valve should be installed on the hot water supply side (out- let) of the unit. (Stiebel Eltron Pre-Plumbed Panels include pressure relief valve) 5. The boiler is designed for a connection to copper tubing and/or PEX tubing. If soldering the unit is necessary, please direct the fl...
Primary/Secondary hydronic practices. Call Tech Support (1-800.805.5384) for assistance. Sample: HSPS120LT 1 Zone Panel: For more information on Stiebel Eltron pre-plumbed panels and zoning options for this boiler please visit www.hydro-shark.com or call 800.805.5384. WWW.HYDRO-SHARK.COM HYDROSHARK|...
Page 14
(with space heating panel(s)) with one heat source. The Stiebel Eltron DHW Integrator Panel integrates with a wide variety of boilers and delivers “Priori- ty” potable heated water with no storage tank and hydronic space heating in a small reliable package.
Owner’s Guide CONGRATULATIONS Congratulations and thank you for choosing our micro boiler. Before use, we recommend that you read through this owner’s guide carefully. Keep this manual for future reference. If you need an additional manual, contact the manufacturer or your local distributor.
TROUBLESHOOTING General Symptom Possible Cause Solution No Hot Water •No Power •Utility Controlling Load •Safety Th ermal Cut Off Tripped •Reset Th ermal Cut Off •Not Enough Flow Rate To Activate •Wrong Size Pump •Plugged Flow Sensor •Activate Th ermostat/ Clean Flow Sensor Water Not Hot Enough •Water Flow Too High...
Set Point Knob Board, HydroShark 12 to HydroShark 36 292575 Housing, HydroShark 7 to HydroShark 10 291851 Electronic Control Device Board, HydroShark 7 to HydroShark 10 283455 Code Plug, HydroShark 7 to HydroShark 10 292578 Back Panel, HydroShark 7 to HydroShark 10...
Boiler Pressure Drops Table (Boilers HydroShark 7 to HydroShark 36) This table is used for sizing Primary (Boiler) Circulator All boilers must use Primary/Secondary circuitry. This is used to create Hydraulic seperation between the Boiler and Emitter circulators allowing you to create 57.5...
Page 20
STIEBEL ELTRON, Inc. 17 West Street | West Hatfield MA 01088 Tel. 800-805-5384 hydroshark@stiebel-eltron-usa.com www.hydro-shark.com 4 < A M H C M O = b g i b e a > Subject to errors and technical changes! | Sous réserve d‘erreurs et de modifi cations techniques!