Led Display - SMA SUNNY MINI CENTRAL 6000TL Installation Manual

Pv inverter
Hide thumbs Also See for SUNNY MINI CENTRAL 6000TL:
Table of Contents

Advertisement

SMA Solar Technology AG
6.2 LED Display
Overview
Green
glows continuously
flashes quickly
(3 x per second)
blinks slowly
(1 x per second)
briefly goes out
(approx. 1 x per
second)
is not glowing
Grid Feeding
After a fault-free grid connection of the Sunny Mini Central, it takes approximately one minute until
the green LED is continuously on. The blink codes shown before that only have the purpose of
indicating the initialization of the Sunny Mini Central and the process of controlling whether the power
supply requirements are fulfilled.
Installation Guide
Red
is not glowing
glows continuously
is not glowing
glows continuously
is not glowing
glows continuously
is not glowing
is not glowing
glows continuously
The green LED illuminates
continuously
Yellow
is not glowing
is not glowing
glows continuously
is not glowing
is not glowing
is not glowing
is not glowing
is not glowing
is not glowing
glowing/flashing
is not glowing
glowing/flashing
SMC6-8TL-IEN093231
Commissioning
Status
OK
(grid feeding)
disturbance
OK
(initialization)
OK (stop)
disturbance
OK
(waiting, grid
monitoring)
disturbance
OK
(derating)
OK
(overnight shutdown)
disturbance
disturbance
disturbance
43