22
Vent Configuration: Horizontal Termination (no vertical rise)
•
NOTE: A Wall thimble (part #58DVA-WTU) is required.
•
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
positions.
•
NOTE: When venting horizontally, use minimum vent kit "C"
installation, an additional 45° elbow is required.
Vent with No 45˚ Elbow
3 feet (0.915m)
0 feet
Vent with 1 45˚ Elbow
3 feet (0.915m)
0 feet
© Travis Industries
Installation
Optional 45 Elbow
45 Elbow
(for qualified installers only)
(96200316). If venting from a corner
Termination
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Min. 6" (152mm) Horizontal Section
Max.48" (1219mm) Horizontal Section(s)
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Min. 6" (152mm) Horizontal Section
Max. 24" (610mm) Horizontal Section(s)
4100728
100-01254_000