APPLICATIONS
CONDENSATE DRAIN VALVE
The temperature- -activated drain valve opens when
Whether you are designing a new structure or
the outdoor temperature drops below 55˚ F (12.8˚ C)
replacing packaged terminal air conditioning units in
to prevent water from freezing in the basepan.
an existing building, Gree GA Series will meet your
needs.
SEAMLESS BASEPAN
•
Hotels and motels
Seamless drawn basepan walls add protection against
•
Nursing homes and assisted living care
water accumulation resulting from storm- -driven rain
centers
with heavy wind.
•
Offices
Gree's deep basepan holds up to 1-3/4 gallons (6.6
•
Apartments
liters) of water without spilling. Closed cell foam
•
Single- -family dwellings
insulators are located between the basepan and coils,
•
keeping coils from direct contact with the basepan
Home conversions and residential add- -ons
and providing additional protection against corrosion.
NEW CONSTRUCTION
The Gree GA series Packaged Terminal Air
Conditioning (PTAC) unit is designed to meet the
needs of the architect, engineer, and contractor. For
CONDENSATE REMOVAL
unit installation, Gree's expert support network will
assist in all applicable aspects of the construction
Gree's GA series has a new condensate (water)
project, from preparing a budget to start-up.
disposal system. The suction port, along with the
ADVANTAGES FOR NEW
slinger ring, draws in water which is sprayed up onto
CONSTRUCTION
the outdoor coil. The water then evaporates, thus
Design Flexibility for the Architect/Engineer
providing better disposal of excess condensate and
improving unit efficiency.
•
Whisper- -quiet performance, indoors and out
NOTE: If it is necessary to control 100% of the
•
No bulky duct system
condensate, the Drain Kit (Part No.: DRAIN-KIT-4PK)
•
No separate equipment room
is recommended.
•
No water towers or additional cooling
equipment
•
No complex match- -up of different HVAC
components
•
Less sensitivity to building orientation (sun,
wind, shade)
•
Optional architectural grille to permit custom
exterior appearance
Initial Cost Savings for the Building Owner
•
No expensive component HVAC system
purchase
•
No
equipment
engineering staff
•
Two- -part delivery to minimize on- -site
damage
•
Weather- -protected wall sleeve that goes in
place during construction; chassis that slides
in place after construction
•
No seasonal changeover required for cooling
or heating - - units are self- -contained comfort
systems
room
or
maintenance
Lower Operating Costs and Reliable Comfort
for The Occupant
•
Heat pump models offer substantial savings
over models with conventional electric
resistance heaters
•
Individual units allow tenants to choose the
degree of comfort and operating economy.
•
Rapid servicing reduces downtime: complete
chassis can be replaced in minutes without
disrupting other occupants.
•
Each unit operates independently of other
units in the building. No dependency by
building on central HVAC system.
RETROFIT/REPLACEMENT
Condensate Drain Valve Prevents Water
If you are replacing a unit in an existing wall sleeve,
from Freezing in Basepan
your options include:
•
Replace the existing wall sleeve with the
the polymer wall sleeve. See accessory sleeve
section for selecting the correct sleeve for
your application.
NOTE: in most cases, when replacing the
SLINGER
RING
wall sleeve, the exterior grille must also be
replaced.
•
Use an existing sleeve and exterior grille. The
Gree GA series PTAC will fit into:
The following major competitors' wall
—
sleeves/grilles: Carrier, GE, Amana,
Trane, Friedrich and Bryant, and NO
accessory retrofit kit is required.
Condensate Removal System
— Friedrich T series and ZoneAire wall
sleeves, with a required wall sleeve
extension (see accessory Friedrich
Retrofit Wall Sleeve Adapter).
12
4
A07550
CONDENSATION
SUCTION PORT
CONDENSER SECTION
A07678