3. Connecting Power

The unit is supplied with a 39-inch (1 meter) AC input cable. If a factory connector was not ordered, Table 1
describes how to connect power to your LEKO LITE Luminaire . Field wiring of the LEKO LITE Luminaire is
straight forward. The following wiring scheme is required:
WARNING! Risk of Fire or Injury! LEKO LITE Luminaires must be grounded per local and/or national codes. Any
installed connector must have the required cord grip and be rated at or above the voltage and wattage or voltampere
values marked on the luminaire.

4. Mounting

WARNING! Before attempting any installation or service, disconnect all power at power source. Dimming the
luminaire does not disconnect power. Installation and service should only be performed by a trained and qualified
professional.

Using Supplied C-Clamp

As illustrated in
mounting hole at top of yoke, install another washer, then thread bolt into clamp. Securely tighten bolt into clamp (but
do not overtighten).
To mount on a telescopic stand, reverse the yoke under the luminaire and bolt to stand. Please note luminaire
orientation (see note in

Safety Cable

A safety cable* MUST always be used when rigging luminaires on bars, truss, etc. A safety cable should be routed
through both the luminaire handle and yoke assembly. You should always consult and follow all local and national
codes and regulations for mounting and installation of luminaire.
Note: *Safety cables are sold separately and available from Philips Strand Lighting. Refer to
Luminaire Clamps & Safety Cable" on page 4
8
INSTALLATION AND SET UP
Table 1: LEKO LITE Luminaire AC Input Wiring
Wire Color
Black
White
Green/Yellow
Figure
4, at yoke assembly, thread clamp mounting bolt (with washer installed) through center clamp
Figure 4: Luminaire Mounting
Figure
4).
Purpose
Main / Line (120 to 240VAC)
Neutral
Ground
Center Clamp Mounting Hole
Yoke Assembly
Luminaire Handle
NOTE: To avoid premature lamp failure it is
essential that the luminaire is always mounted so
the yoke is horizontal and with the lamp base down
with the lamp adjustment knob is at the bottom of
the rear lamp plate (as shown).