Installation And Set Up Power Requirements; Connecting Power; Connecting To The Dmx512 Network - Philips Selecon User Manual

Pl house light led mkii
Hide thumbs Also See for Selecon:
Table of Contents

Advertisement

PL House Light MKII LED Luminaires
INSTALLATION AND SET UP
1. Power Requirements
WARNING! The PL House Light MKII LED Luminaire should be connected to a constant circuit or a relay device.
It should never be connected to a dimmer or circuit controlled by a dimmer.
The PL House Light MKII LED Luminaire operates on single phase 100 to 240 volts
AC (+/- 10%, auto-ranging). The luminaire contains an auto-ranging power supply.
Depending on supply voltage, each luminaire can draw up to 140 Watts.
WARNING! Maximum Allowable Input Current of 20 Amps (maximum power supply limit of 140 Watts). A
maximum of eight (8) PL House Light MKII LED Luminaires can be daisy-chained on a circuit. Do not overload
circuits! Must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector. Doit être
alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur. Do not overload
circuits!
IMPORTANT AC POWER CONNECTION NOTES:
For support call +1.214.647.7880
or visit www.seleconlight.com
▲ CONFORMS TO UL STD 1598 & UL STD 8750; CERTIFIED TO CSA STD
C22.2 NO. 250.0 & CSA STD C22.2 NO. 250.13
▲ MIN 90°C SUPPLY CONDUCTORS. LES FILS D'ALIMENTATION 90°C MIN.
▲ DRY LOCATIONS ONLY. POUR EMPLACEMENTS SECS SEULEMENT.
▲ SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 40°C
PEUT ÊTRE UTILISÉ À UNE TEMPÉRATUREAMBIANTE N'EXCÉDANT PAS 40°C (S24-L2)
▲ DO NOT INSTALL INSULATION WITHIN 153 mm (6 in) OF ANY PART OF THE LUMINAIRE. NE PAS METTRE
L'ISOLANT À MOINS DE 153 mm (6 po) DE TOUTE PARTIE DU LUMINAIRE.
▲ NOT FOR RESIDENTIAL INSTALLATION OR USE. PAS POUR L'INSTALLATION HABITATION OU A USAGE.
a. Must be supplied by a branch circuit protected by a maximum 20 Amp circuit protector. Doit être
alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur.
b. Use only approved cable types.
c. Do not overload circuits!
d. Do not connect PL House Light MKII LED Luminaires to dimmed circuits.

2. Connecting Power

Refer to
"Mounting and Connecting Power" on page 8

3. Connecting to the DMX512 Network

Basic DMX512 installation consists of connecting multiple PL House Light MKII LED Luminaires together (up to
30 luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the
DMX connector on the first PL House Light MKII LED Luminaire. Another cable runs from the other DMX
connector on the first unit to a DMX connector on the next PL House Light MKII LED Luminaire (or DMX512
device to be controlled).
Model:
Input Voltage:
Wattage:
Serial Number / Date Code:
for installation and power connections.
User's Manual
AC Input Only!
PLHLIBMKII
100-240 VAC, 50/60Hz
140 Watts (max.)
Label: 04.9688.2005
Power Requirements
7