3. Beam Shutter Operation

CAUTION: When adjusting the luminaire's beam shutter, it is important to wear protective gloves. The luminaire
produces extreme heat and all surfaces could cause serious burns if touched.
Each LEKO LITE Luminaire is equipped with four independent shutters (as shown in
light as desired. After the luminaire is installed and positioned, move the shutters in or out as required.

4. Gobos

Each LEKO LITE Luminaire is capable of holding two gobo holders, each containing one "B" sized glass or steel
gobo. Note, each LEKO LITE Luminaire is supplied with one gobo holder. additional holders can be purchased from
your local Philips Strand Lighting Authorized Dealer. For more information, refer to
/ Gobo Holders / Iris" on page
To install or change a gobo:
Step 1. As shown in
open gobo access panel.
Step 2. Install gobo into gobo holder in desired orientation.
Step 3. Slide gobo holder into luminaire gobo slot.
Step 4. Close gobo access door. Make sure gobo holder handle fits inside one of two slots in gobo access panel.
Step 5. Hand tighten gobo access panel retaining knobs.
1 2
FOCUS AND BEAM ADJUSTMENTS
Beam Shutters
(4 Each)
Front View
Figure 8: LEKO LITE Luminaire Beam Shutters
4.
Figure
9, loosen, but do not remove, two retaining knobs that secure gobo access panel. Slide
Detail A
See Detail
A
Figure 9: LEKO LITE Luminaire Gobo Holder and Gobo Installation
Gobo Access Panel
Retaining Knobs
(2 Each)
Gobo
Area
Gobo Holder
LEKO LITE Luminaires
Figure
8) to block or shape
Move beam shutters
in and out as desired.
"LEKO LITE Luminaire Frames