Installation And Set Up Power Requirements; Connecting Power; Connecting To The Dmx512 Network - Philips Selecon PL1 Series Installation & User Manual

Selecon led luminaires
Table of Contents

Advertisement

Installation & User's Manual
INSTALLATION AND SET UP
1. Power Requirements
The PL1 LED Luminaire operates on 120 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto-
ranging power supply. Depending on supply voltage, each luminaire can draw up to 1.91 amps.

2. Connecting Power

If the unit is supplied with an AC input cable, Table 2 describes how to connect power to your PL1 LED Luminaire .
Field wiring of the PL1 LED Luminaire is straight forward. A total of 3 wires/conductors need to be brought to the
unit. The following wiring scheme is required:

3. Connecting to the DMX512 Network

Basic DMX512 installation consists of connecting multiple PL1 LED Luminaires together (up to 30 luminaires) in
"daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX connector on
the first PL1 LED Luminaire. Another cable runs from the other DMX connector on the first unit to a DMX
connector on the next PL1 LED Luminaire (or DMX512 device to be controlled).
6
INSTALLATION AND SET UP
Table 1: PL1 LED Luminaire Voltage vs. Current
Voltage (AC)
Total Current (A)
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
240
Table 2: PL1 LED Luminaire AC Input Connections
Wire Color
Brown
Blue
Green/Yellow
1.91
1.72
1.56
1.43
1.32
1.23
1.15
1.07
1.01
0.96
0.91
0.86
0.82
0.78
0.75
0.72
Purpose
Main / Line (120 to 240VAC)
Neutral
Ground