  • Page 1 ARITERM-VTT-S-07229-11.1 INSTALLATION AND OPERATING INSTRUCTIONS • Ariterm Biomatic+ 20...
  • Page 2: Table Of Contents

    Keep this manual in a safe place for future reference. Read this manual carefully before start- Pipe installations ..................7 ing to use your Ariterm Biomatic+ pellet heating centre. The power of the pellet burner de- Wiring diagram .................... 8 pends on how many pellets can be fed into and burned in the burner head during one hour.
  • Page 3: Technical Data

    9 kW resistance about 10 kW (depending on equipment) 7. Hot domestic water 22 mm Cu ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 3/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 4: Functional Description

    FUNCTIONAL DESCRIPTION SAFETY AND ALARMS Heating with the Ariterm Biomatic+ pellet heating centre is similar to oil heating in many For safety reasons, the pellet heating centre and fuel store must be placed apart from each other ways. The main difference is that heating with solid fuel produces a certain amount of ash, to prevent possible damage.
  • Page 5: Control Panel

    C button: exiting menus / acknowledging warnings / ac- knowledgement of setting Enter button: selecting settings / go to sub-menu ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 5/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 6: Boiler Installations

    ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 6/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 7: Pipe Installations

    10. SAFETY VALVE 11. FILLING VALVE 12. FEED MIXING VALVE 13. DOMESTIC WATER CIRCULATION PUMP ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 7/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 8: Wiring Diagram

    WIRING DIAGRAM ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 8/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 9: Start-Up And Stop

    (hot or cold start depending on the temperature of boiler water). ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 9/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 10: Burner Settings

    62 ºC, the electrical resistance turns off. Settings: Heating method: pellets + 6. Blower 12. Connector panel electricity and El step = 1 ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 10/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 11: Menu Structure

    Temperature Auger external Time • Manual Warmstart amount Coldstart amount Coldstart settings ABM+20 - v110311 ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 11/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 12: Adjustments Menu

    Operating time of the 6 kW electrical resistance. El 2 Operating time of the 3 kW electrical resistance ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 12/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 13 Cleaning x (100) h 0-250 h cleaned. To be determined on the basis of experience. ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 13/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 14: Menu Structure

    MENU STRUCTURE Accessories menu Heat regulation The standard equipment of the Ariterm Biomatic+ pellet boiler includes a heat regulator that Menu Setting Description can be used to control at most two heating circuits. A temperature graph for supply water tem- Fan power adjustment according to residual oxygen.
  • Page 15: Heating Circuit Settings

    Outdoor temperature -20 ºC Flow water 55 ºC Outdoor temperature +20 ºC Flow water 10 ºC ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 15/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 16: Heat Regulation Examples

    1 ºC. Flow water sensor Indoor temp. sensor Outdoor temp. sensor ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 16/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 17: Regulating Unit Installation And Use

    The room temperature unit can be installed for the and the cable for metering signals in the Output menu with the settings High fan and Ariterm Biomatic+ 20 from manufacturing number. to the connection on the reverse of Intermediate fan. These values must not be changed.
  • Page 18: Alarms And Troubleshooting

    ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 18/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 19 Service menu. The setting 0 means that the function is off. object. auger or blocking feeder. ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 19/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 20: Decommissioning

    GUARANTEE AND DECOMMISSIONING MOST COMMON SPARE PARTS Guarantee Product no. Description For Warranty Issues Ariterm Sweden AB refers to our local Distributor. 5936 Overheat protection EGO 55.33412.010 5356 Gasket 2x183x200, burner Decommissioning 5787 Grundfos UPS 25-40 pump An end-of-life boiler is suitable for scrapping. Its plastic parts are landfill waste.
  • Page 21: Service And Maintenance

    Make sure thatthe burner wires do not get the ash box. delivery or when you change suppliers. damaged. ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 21/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 22: Boiler Cleaning

    Combustion chamber cleaning used and must be replaced with a new one. (as needed) Ash box emptying ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 22/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 23 9. Install the convection channel hatch and the rocker remove any ash. Push the brush up and down again. switch. ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 23/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 24: Wood Pellets As Fuel

    NOTE! Moisture content less than 10% The Ariterm Biomatic + series boilers are suitable for burning pellets of diameters ranging from Ash content less than 0.7 weight % 6mm through to 12mm. The burner is factory set for 8mm wood pellet having a mean density of 650kg/m3.
  • Page 25: Feeding System

    More information on the installation of PS300/Feedo can be found in separate manuals. More information on the installation of Depo/Feedo can be found in separate manuals. ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 25/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...
  • Page 26: Declaration Of Conformity

    Clean Air Act requirements The Ariterm Biomatic+ series boilers have been recommended as suitable for use in smoke control areas when burning wood pellets. ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB •...
  • Page 27: Installation Record

    Flue gas temperature - Min Combustion efficiency Draught mm Auger % Blower % Dealer / Installer Installer Date ARITERM-VTT-S-07229-11.1 ARITERM SWEDEN AB • ARITERM OY 27/32 • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 •...