Ariterm Biomatic+ 20i/40 Installation And Operating Instructions Manual

Ariterm Biomatic+ 20i/40 Installation And Operating Instructions Manual

Advertisement

INSTALLATION AND OPERATING
INSTRUCTIONS
i
• Ariterm Biomatic+ 20
/40
i
• Ariterm Biomatic+ 20
/40
i
• Ariterm Biomatic+ 20
/40
i
i
Light
i
Ultra-Light
Version 2.0 • 12.04.2017
5P01781-A
5P01781-B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Biomatic+ 20i/40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ariterm Biomatic+ 20i/40

  • Page 1 5P01781-A 5P01781-B INSTALLATION AND OPERATING INSTRUCTIONS • Ariterm Biomatic+ 20 • Ariterm Biomatic+ 20 Light • Ariterm Biomatic+ 20 Ultra-Light Version 2.0 • 12.04.2017...
  • Page 2: Table Of Contents

    Technical data ...............3 tally friendly, self regulating central heating boiler intended for heating of residential houses and production of domestic hot water using pellets. Standard equipment of the Ariterm Functional description ...........4 Biomatic+ 20 includes true lambda control, automatic heating circuit regulation, Safety and alarms ............4...
  • Page 3: Technical Data

    1N~, 50 Hz 1N~, 50 Hz Dimensions of Ariterm Biomatic+ and Biomatic 40i. Dimensions in parentheses specific dimension of Ariterm Biomatic+ 40i. Fuse size Standard model 9 kW immersion Standard model 9 kW immersion 1. Drain valve DN 15, internal thread 6.
  • Page 4: Functional Description

    FUNCTIONAL DESCRIPTION SAFETY AND ALARMS Heating with the Ariterm Biomatic+ 20 pellet heating unit is similar to oil heating in For safety reasons, the Biomatic+ 20 and fuel store must be placed apart from each many ways. The main difference is that heating with solid fuel produces a certain amount other to prevent possible damage.
  • Page 5: Control Panel

    Pellets are fed to the Safety zone against burner head from below Combustion fan Burner screw fire in the back (underfeeding principle) 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 5/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 6: Boiler Installations

    The installation must always be carried out in accordance with, at the time being, valid local Before installing the boiler, the heating system must be flushed and checked by means standards and regulations, as well as the Ariterm Installation and Operation Instructions. of a water-pressure test. After installation, make sure that all joints are tight.
  • Page 7: Pipe Installations

    6. Floor heating network manifolds 7. Radiator heating network 8. Expansion vessel 9. Service shut-off valve 10. Safety valve 11. Filling valve 12. DHW mixing valve 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 7/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 8: Wiring Diagram Biomatic+ 20

    Brown Alarm relay Brown Tank sensor (top) Black Black Black Circulation pump Tank sensor (bottom) Fuse w. pump Black Black BM61011v1 140822 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 8/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 9: Wiring Diagram Biomatic+ 40

    +12V Brown Alarm relay Brown Tank sensor (top) Black Black Fuse w. pump Circulation pump Tank sensor (bottom) Black Black 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 9/32 Installation and operating instruction • Version 2.0 • 12.04.2017 BM61021v1 140821...
  • Page 10: Start-Up, Start And Stop

    Click at “Update”. Now you will access Ariterm Local Control of the boiler via the web interface and will be Repeat until the external feeder has fed a couple of liters of pellets into a bucket.
  • Page 11: Burner Settings And Parts

    Press the burner control The picture shows 20 kW burner. switch for more than 10 seconds until the flue gas fan starts to pulse. 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 11/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 12 You enter the control with Username/Password. Further information at The present operating mode of the burner, On or Off status of the burner, Sync status, ”Connecting to Ariterm web interface” under ”Start-up, Start and Stop”. Boiler temperature, Room temperature, Outdoor temperature, Estimated pellet level,...
  • Page 13 MENU STRUCTURE ARITERM LOCAL/PORTAL CONTROL Alarm Alarm: Manage emails In the “Alarm” menu you can see current alarms and are able to confirm them. In the ”Alarm: Manage emails” menu you can add receivers of alarm emails and You can also view and search the alarm history.
  • Page 14 MENU STRUCTURE ARITERM LOCAL/PORTAL CONTROL Settings: Main Settings: Maintenance In the ”Settings: Main” menu you are able to set the boiler start and stop temperatures In the ”Settings: Maintenance” menu you are able to set two different alarm timers. (40-90 ˚C) , desired room temperature and set the burner in On/Off mode.
  • Page 15 MENU STRUCTURE ARITERM LOCAL/PORTAL CONTROL Settings: Immersion heater Settings: Pellet Storage In the ”Settings: Immersion heater” menu you can set start and stop temperature of In the ”Settings: Pellet storage” menu you can manually force feed the external feed the immersion heater.
  • Page 16 MENU STRUCTURE ARITERM LOCAL/PORTAL CONTROL Settings: Tank mode Profile At ”Settings: Tank mode” you can activate Tank mode, set ”Boiler temperature limit” In the ”Profile” menu you can edit your profile.To be able to edit your profile you must and ”Tank pump start temperature”.
  • Page 17 In ”Network” menu you are able to scan and select local networks if to connect the boiler In the ”User” menu you can view all users of the boiler. to internet, changing from Ariterm Local Control (using the boiler integrated AP) to Ariterm Portal Control.
  • Page 18 MENU STRUCTURE ARITERM LOCAL/PORTAL CONTROL Users: Create user Schedule In the ”Users: Create user” menu you can add new users. You are not able to add users in In the ”Schedule” menu you can see what profile - ”Schedule”, ”Work”, ”Home” or a higher user level than your own.
  • Page 19: Heat Circuit Settings Ariterm Local/Portal

    HEAT CIRCUIT SETTINGS ARITERM LOCAL/PORTAL CONTROL Schedule (option): Work/Home Schedule (option): Schedule In ”Work” and ”Home” profiles you can set desired room temperatures during the day In the ”Schedule” profile you edit the weekly heating schedule defining what weekdays for days away from home ”Work”, or at home ”Home”. Profiles to be activated, either the boiler is to operate according to ”Work”...
  • Page 20: Heat Circuit Settings And Connections

    CRB122 Shunt motor unit with Ariterm Local/Portal Control PWM pump For the first heating circuit the CRB122 unit operates together with the Ariterm Local/Portal Connect the PWM regulation cable to the fast connectors, blue on blue and brown on brown. (B) Control.
  • Page 21: Heat Circuit Settings And Connections

    NOTE! The return temperature shall be regulated, with a thermic valve, to at least 60 ˚C. 11. Solar coil. 12. DHW cold inlet from mixing valve. 13. DHW warm outlet to mixing valve. 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 21/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 22: Alarms And Troubleshooting

    5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 22/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 23: Guarantee And Decommissioning

    GUARANTEE AND DECOMMISSIONING MOST COMMON SPARE PARTS Guarantee Biomatic+ 20 spare part list Biomatic+ 40 spare part list For Warranty Issues Ariterm AB refers to our local Distributor. Product no. Description Product no. Description 5936 Thermal protection 5936 Thermal protection...
  • Page 24: Service And Maintenance

    Make sure that the burner wires do not get damaged. 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 24/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 25 Combustion chamber cleaning (as needed) Ash box emptying 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 25/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 26 Repeat a couple of times. 9. Replace the Turbulator cover plates and 10. Replace the Convection cleaning hatch the Turbulator rocker. and fasten the start knobs. 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 26/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 27 Repeat a couple of times. 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 27/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 28: Wood Pellets As Fuel

    Due to their small size, the pellets move freely in the feeding augers. NOTE! The Ariterm Biomatic + series boilers are suitable for burning pellets of diameters ranging from 6 mm through to 8 mm. The burner is factory set for 6 mm wood pellet.
  • Page 29: Feeding System

    The capacity of the storage is 450 liters and it’s filed by an integrated grid at the top. quietly feeds pellets from the silo. Ariterm Depo is designed to be used in combination The Ariterm PF450 may also be used as intermediate storage.
  • Page 30: The Clean Air Act 1993 And Smoke Control Areas

    BeQuem 40, Ariterm Biomatic+ 40 Light with pellet burner BeQuem 40 and Ariterm Biomatic +40 Ultra-Light with pellet burner BeQuem 40 have been recommended for exemption under the Clean Air Act when burning wood pellets and operated in accordance with these instructions.
  • Page 31: Installation Report

    Blower % Auger % Flue gas temperature - Min Combustion efficiency Draught mm Auger % Blower % Dealer / Installer Installer Date 5P01781-A / 5P01781-B ARITERM AB • ARITERM OY 31/32 Installation and operating instruction • Version 2.0 • 12.04.2017...
  • Page 32 5P01781-A 5P01781-B ORGANISATION CERTIFIED BY Ariterm AB / Flottiljvägen 15 / 392 41 Kalmar / Sweden / +46 (0)480 442850 / info@ariterm.se / www.ariterm.se...