    CONTENTS General ..................3 Installation ................4-5 Laddomat 21 Connection diagram ........6 Temperature control valve ............7 About burning wood ...............8 Operation ................9-11 Service and maintenance ..........12-15 Measurements and connections .......... 16 Technical data................ 17 Guarantee ................17 Flue gas fan control unit ............18 Content of delivery and installation ........
  • Page 3: General

    Vedo should be connected to a warm water accumulator. In proportion to its efficiency, Vedo is small and therefore easy to fit in available spaces. The boi- ler room is not required to have the highest fire safety classification; EI 30 is sufficient. To make optimal use of the boiler’...
  • Page 4: Installation

    Flue gas fan The Vedo has versatile assembly options that allow it to be fitted with different chimney so- lutions. The standard delivery always includes a flue gas fan. The standard connection to the chimney is straight up (image 1). Make sure to leave enough space for cleaning when installing the pipe.
  • Page 5: Installation

    INSTALLATION Plumbing connections Before installation of the boiler, the heating system must be flushed and a water pressure test carried out. The tightness of connections must be ensured after installation. The factory is not responsible for damage caused by leaking connections. Relief valve installation The pressure relief valve must be CE-approved with a maximum opening pressure of 1.5 bar and a minimum size of DN 15.
  • Page 6: Laddomat 21 Connection Diagram

    CONNECTION DIAGRAM Room temperature sensor Exp. Radiator temperature sensor Hot water A T-pipe with a min. vessel diameter of 1 ¼” Cold water Radiator improves ventilation Automatic shunt Mixer valve Radiator pump Flue thermostat Relief valve Shunt valve Electric resistor Warm water accumulator Tank...
  • Page 7: Temperature Control Valve

    TEMPERATURE CONTROL VALVE The Ariterm Vedo boiler must be installed in connection with a warm water accumulator. This improves its functionality and extends its life span substantially. By installing the boiler as presented here, it is possible to make the boiler temperature rise quickly and to maintain a steady, high temperature when the boiler is being used.
  • Page 8: About Burning Wood

    ABOUT BURNING WOOD Before starting the boiler, check the following: • Heating network and boiler are filled with water, pressure at least 0.5 bar • If there is a smoke pipe damper, make sure that it is open • The heat supply pump is switched on •...
  • Page 9: Operation

    OPERATION The use of wood in the Ariterm Vedo Ariterm Vedo is designed for the combustion of solid fuels in densely populated neighbour- hoods. It has been tested and approved in accordance with the latest wood-fired boiler requi- rements. The approval requires both ceramic grates and transfer of heat into an accumulator.
  • Page 10: Starting The Fire

    OPERATION Starting the fire: • Open the smoke pipe damper. Adjust primary air vent to 4 and secondary air vent to 5 (on 1 to 7 scale). Adjust primary air vent to 4. Adjust sekundary air vent to 5. • Start up the exhaust fan.
  • Page 11 Oil use Ariterm Vedo is also compatible with using oil as fuel. The oil burner is installed on the pellet burner hatch using an oil burner flange, which is available as an accessory.
  • Page 12: Service And Maintenance

    SERVICE AND MAINTENANCE The boiler will function properly and have a long service life when the following matters are ta- ken care of: • The boiler should be located in a dry space. • The boiler should always be operated within the recommended limits. •...
  • Page 13 SERVICE AND MAINTENANCE Remove all turbulators. Clean the boiler convector by brushing the convector pipes clean. Make sure that the fire door damper Make sure that the fire door damper closes when you close the feeding opens and closes as you use the hatch.
  • Page 14 SERVICE AND MAINTENANCE Other maintenance procedures Adjustment of the hatches Check that the hatch sits tightly. A leaky fee- ding hatch will cause wood to combust in the wrong place. Tighten the hatches by adjusting the lock handle and hinge pieces. From time to time, you should check that the gap between the deflectors and the storage The tightness of the hatches is important for...
  • Page 15: Service And Maintenance

    SERVICE AND MAINTENANCE Adjusting the hinge: • Unscrew both mounting screws of the hinge piece enough to move the hinge. • Move the hinge piece slightly in the direc- tion of the boiler. • Tighten the mounting screws slightly and test whether the hatch now sits more tightly on the hinge side.
  • Page 16: Measurements And Connections

    MEASUREMENTS AND CONNECTIONS Part Name Unit Feeding hatch Stoking hatch Primary air vent Secondary air vent Convector door Top door Bottom door Outlet to accumulator DN 32 Expansion vessel outlet DN 25 Cooling spiral Cu 15 Return from accumulator DN 32 Draining outlet DN 15 Water thermometer / pressure gauge...
  • Page 17: Technical Data

    1100 – 2500 L Maximum length of firewood 0,5 m Guarantee For Warranty Issues Ariterm Sweden AB refers to our local Distributor. Removal from use A boiler that has reached the end of its useful life can be used for scrap.
  • Page 18: Flue Gas Fan Control Unit

    General A flue gas fan is a standard equipment for the Ariterm Vedo. The fan system includes a control unit which runs the fan at a set speed during combustion periods. When a combustion period is over, the fan stops automatically. The fan unit can also be preset to work during pellet burning, in which case the rotating speed is set to alternate in line with standby mode and active combustion cycles.
  • Page 19: Content Of Delivery And Installation

    CONTENT OF DELIVERY AND INSTALLATION The delivery includes: Control unit Flue gas sensor Boiler water sensor Extension cable 230 VAC 50Hz P1=Flue gas fan P3=Loading pump T1=Flue gas sensor T2=Boiler water sensor T6=Active combustion alert from the pellet burner (voltage-free input) NOTE: If the pellet burner being used cannot supply voltage-free contact data, this data can be accessed from the pellet burner’...
  • Page 20: Operating Modes And Menus

    OPERATING MODES AND MENUS Testing Testing Settings WOOD Tank pump Towards the end of active combustion, the If you have selected the flue gas fan, loading Fan temp. limit pump function and boiler water sensor from temperature of the flow gases will start to 30°C Tank pump Fan / delay time...
  • Page 21 OPERATING MENUS Settings WOOD Even if the loading pump is switched ON, it NOTE: The operating mode selection must Fan temp. limit 90°C will not rotate if the boiler water temperature be done within a minute of switching the Fan / delay time 10min is below the pump starting temperature (Set- control unit on.
  • Page 22: Boiler Water

    USER MENUS Fan delay time: When the combustion period In the pellet operating mode, the fan is always running. When the burner is in standby is launched by pressing the + button, the mode, the fan uses the lower set value Fan fan start-up delay begins.
  • Page 23: Declaration Of Conformation

    MANUFACTURES DECLARATION...