Ariterm retailer. Th e retailer supplies required spare parts and authorized service- man makes the necessary adjustments and combustion gas analysis when replacing spare parts. Ariterm reserves the right to alter any details and specifi cations without prior notice. ARITERM SWEDEN AB Installation, Operation & Maintenance -...
Power supply 400 V 50 Hz Supply cable MMJ 4x2,5s Electrical data *) The simpler model of Biomatic+ 20, Biomatic+ 20 Ultra Light, is delivered Fuse size 3x16 A Power in operation 9000 W without electric heater, heat exchanger and internal circulation pump.
Page 4
Supply cable MMJ 4x2,5s 12. Air valve Electrical data A-dimensions including comb.fl ue pipe Fuse size 3x16 A 13. Ash compression Power in operation 9000 W is app. 2000 mm ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 4/24...
Sweeping takes place through the rebox door or through a cleaning hatch on top of Biomatic+ 20/30 belongs to the most effi cient state-of-the art pellet boilers in today’ s the boiler. Ashes collect in the oversized ash box that is attached to the ash door. Th e marketplace.
Boiler cement is suitable for sealing. Recommended fl ue gas requirements for Biomatic+ 20/30: brick chimney lined with a Ø 100 mm (130 mm for 30) acid proof thin-walled tube or an acid proof Ø 100 mm:s (130 mm for 30) element chimney.
An open system with 500 litre water volume demands at least a 35 litre expansion vessel and a 1500 litre system volume a 80 litre expansion vessel * System volume = boiler volume + storage tanks + piping volume + radiator volume. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 8/24...
Adjust the red needle of the pressure gauge to the same value as the big needle. Heating with electric heating element Ariterm Biomatic+ 20 and Biomatic+ 30 has been fi tted with a factory wired 3-phase 6/9 kW electric heating element.
Burning solid fuels, even if operation is automated, normally calls for a little more care and maintenance than oil heating. For Biomatic+ 20/30 maintenance has been mini- mized as the result of well planned design and a big ash box holding 50 litres.
Page 11
It is a larger, wheeled carriage, which is easier to important not to vacuum hot ash because of the empty. (Extra equipment) fire risk. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 11/24...
ATTENTION! To eliminate the risk of the connecting hose becoming overfi lled with pellets, the boiler should not be combined with any other external feeding system. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 12/24...
Back flow preventer For details about the various alarm conditions please refer to ”Troubleshooting”. plate Supply control auger Air lock Primary air tube Ignitor tube Burner auger Boiler front ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 13/24...
fi re-start might be necessary after some 3 minutes opera- tion. It is always possible to light the fuel manually using fi re-lighting fl uid. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 14/24...
If you do not press any of the control keys, the control unit will revert to menu 1 automatically after 8 minutes. Th ere are two more service levels, but they are reserved for the service technician only. On (-Off) Service Reaching the menu level ”Service” ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 15/24...
“forward” to the next screen, if you want to view the pellets store data. Displays the number of operating days at the avera- Estimated time left For information only. ge consumption level in question. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 16/24...
Page 17
Is reset by pressing the Plus/Minus buttons si- Default set vXXXX Cold starts Displays the number of cold starts. les resetting the factory settings. the Plus button. multaneously for 3 seconds. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 17/24...
Shake the drop tube and change the that the inclination of the drop pipe is inclination so that pellets will not get not too gentle. stuck. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 18/24...
Page 19
No and, when necessary, should be repla- fuel has entered into the combus- ced by an authorised technician. tion head. ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 19/24...
Study carefully the fuel performance after new delivery. Moisture content less than 10 % In case of doubt, please contact us at Ariterm. Ash content less than 0.7 weight % • Most of the problems that arise on account of inferior fuel quality are the result of inadequate handling and storage before the fuel reaches the end customer.
Hose 1 m incl. 2 hose clips 0011 Pellets Boiler Pellets storage bin ATTENTION ! max 3 piece feeding holes *) If the refill connection is extended, the extension must be made of metal (no plastic) ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 21/24...
2 x Ø 200 mm Slippery plywood board 16 mm Horizontal stud 50˚ 45x95 mm Store pipe (delivered by Ariterm), 2 x horizontal 80 mm see previous page. The whole length studs 45x95 mm of the store pipe shall be supported.
If these instructions are not followed during installation, operation and maintenance, the obligations of Ariterm AB under the warranty regulations are no longer binding. Ariterm reserves the right to alter any details and specifi cations without prior notice. ARITERM SWEDEN AB Installation, Operation &...
Page 24
ARITERM SWEDEN AB Installation, Operation & Maintenance - 2007.08.14- 24/24...
Need help?
Do you have a question about the Biomatic+ 20 and is the answer not in the manual?
Questions and answers