Rapid Reading Of Alarm Codes; Cancelling The Last Alarm - Electrolux EWM2100 Service Manual

Hide thumbs Also See for EWM2100:
Table of Contents

Advertisement

5.3

Rapid reading of alarm codes

The last three alarm codes can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
→ Press and hold down START/PAUSE and the nearest option button (as to enter the
DIAGNOSTICS), for at least two seconds: the LEDs initially switch off, and then display the flashing
sequence indicating the last alarm.
→ To display the previous alarms press the left button of the START/PAUSE button sequentially.
→ To return to the last alarm, press the START/PAUSE button.
→ The alarm sequence continues as long as the two buttons are held down.
→ The alarm reading system is as described in paragraph 5.2.
→ While the alarms are displayed, the appliance continues to perform the cycle or, if in the programme
selection phase, maintains the previously-selected options in memory.
5.4

Cancelling the last alarm

It is good practice to cancel the last alarm:
after reading the alarm code, to check whether the alarm re-occurs during diagnostics;
after repairing the appliance, to check whether it re-occurs during testing.
1. Select diagnostic mode.
2. Turn the selector (version with knob) or push button P2 (version INPUT) to the tenth
position (reading of alarm).
3. Press and hold down START/PAUSE and the nearest option button (as represented in
figure).
4. Hold down the buttons till the LEDs stop to flash (at least 5 seconds).
N.B. With this operation all the memorised alarms are deleted.
03-2009 SOI/DT-mdm FCPD-dp Quality-fz
14/91
599 70 56-70

Hide quick links:

Advertisement

Table of Contents
loading