Ed6: Communication Failure Between Main Circuit Board And Satellite Board (Input Styling) - Electrolux EWM2100 Service Manual

Hide thumbs Also See for EWM2100:
Table of Contents

Advertisement

ED6: Communication failure between main circuit board and Satellite
ED6
Tests to be performed:
Measure the continuity between
connector J16 (main circuit board)
and J1 (Satellite board
fig. 34).
Is the wiring OK?
Replace the electronic board
(main + satellite) and restart the
diagnostic cycle to check for
further alarms.
J11
J10
J16
Fig.4
03-2009 SOI/DT-mdm FCPD-dp Quality-fz
board (INPUT styling)
NO
YES
J7
J9
J8
Circuit
board
Fit / replace the wiring and restart
the diagnostic cycle to check for
further alarms.
Fig.34
J5
J1
J2
U3
If there are traces of burning on the
80/91
J1
J2
Satellite
board
circuit board, refer to page
ED6
90
599 70 56-70