5.5 TABLE OF ALARMS

Alarm
Possible fault
E00
No alarm
E11
Difficulties in water fill for washing
E12
Difficulties in water fill for drying
E13
Water leakage
E21
Difficulties in draining for washing
E22
Difficulties in draining for drying
E23
Drain pump triac faulty
Fault in "sensing" circuit of drain
E24
pump triac (wrong input signal to
microprocessor)
Electronic pressure switch circuit
E31
faulty (frequency of pressure switch
signal out of limits)
Incorrect calibration of electronic
pressure switch
E32
(The electronic pressure switch
generates a signal with instable
frequency during the drain phase)
E35
Water overflow
Pressure chamber blocked
E38
(water level does not vary for at least
30 sec. during drum rotation
Heating elem. relay sensing faulty
E3A
(input signal to microprocessor
always 0V or 5V)
E41
Door open (after 15 sec.)
03-2009 SOI/DT-mdm FCPD-dp Quality-fz
Action/machine status
----------------
Tap closed or water pressure too low; Drain tube improperly
positioned; Water fill solenoid valve is faulty; Leaks from water circuit
on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty.
Tap closed or water pressure too low; Drain tube improperly
positioned; Water fill solenoid valve is faulty; Leaks from water circuit
on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty.
Drain hose incorrectly positioned; mains pressure insufficient; water
fill solenoid faulty; leakage/blockage of pressure switch hydraulic
circuit; pressure switch faulty.
Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty;
PCB faulty.
Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty;
PCB faulty.
Drain pump faulty; Wiring faulty; PCB faulty.
PCB faulty.
Electronic pressure switch; Wiring; PCB faulty.
Drain tube kinked/clogged/improperly positioned; Drain filter
clogged/dirty; Drain pump faulty;
Leaks from water circuit on pressure switch; Pressure switch;
Wiring faulty; PCB faulty.
Water fill solenoid faulty; Leaks from water circuit on pressure switch;
pressure switch faulty; wiring faulty; PCB faulty.
Motor drive belt broken; Hydraulic circuit pressure switch clogged.
PCB faulty.
Door interlock faulty; wiring faulty; PCB faulty.
Cycle is paused with door locked.
Cycle is paused with door locked.
Cycle is paused with door locked.
Cycle is paused (after 2 attempts).
Safety drain cycle - Cycle stops with
Safety drain cycle - Cycle stops with
Cycle blocked with door closed.
Cycle blocked. Safety drain cycle. Drain
pump always in operation (5 minutes
Cycle blocked with door closed.
15/91
Reset
----------------
----------------
START/RESET
START/RESET
START/RESET
START/RESET
Cycle is paused.
START/RESET
door unlocked.
door unlocked.
Cycle is paused.
START/RESET
on, 5 minutes off etc.).
ON/OFF
Heating phase skipped.
Cycle paused.
START/RESET 36÷38
Alarm
Pag.
----------
21
23
24
26
28
RESET
30
RESET
31
RESET
31
32
RESET
33
34
RESET
RESET
35