E41: Door Open (4-Contact Device) - Electrolux EWM2100 Service Manual

Hide thumbs Also See for EWM2100:
Table of Contents

Advertisement

E41
Instantaneous door interlock with
4 connections.
- fig 28 -
YES
To check the wiring (with the door
open), measure the following
wiring connectors (fig.4):
- between J1-1 and J1-3, the
circuit must NOT be open
(Measure the resistive value of the
PTC).
- between J1-1 and J1-4, the
circuit must be OPEN (Measure
the resistive value of the PTC).
- between J1-1 and J1-2, the
circuit must be OPEN.
Is the system OK?
YES
Check for mechanical coupling
between the door interlock and the
door natch. Is the system OK?
SI
Replace the door interlock.
Is the machine working correctly?
YES
Restart the diagnostic cycle to
check for further alarms.
03-2009 SOI/DT-mdm FCPD-dp Quality-fz

E41: Door open (4-contact device)

Maximum time exceeded (5 pulses for instantaneous)
Detach the connectors and
measure on the component:
- across connectors 3 and 4
open (measure the resistive
- across connectors 2 and 4
NO
open (measure the resistive
- across connectors 4 and 5
(the numbers are printed on
Measure the continuity across
connector J1 (PCB) and the
Replace the circuit board and
restart the diagnostic cycle to
NO
Replace the door natch/the
Replace the circuit board and
NO
restart the diagnostic cycle to
fig. 28
the circuit must NOT be
value of PTC)
the circuit must NOT be
value of PTC).
the circuit must be OPEN
the component).
Is the door safety interlock
is OK?
(fig. 28)
YES
door interlock connector.
Is the wiring OK?
YES
check for further alarms.
door.
check for further alarms.
If there are traces of burning on the
37/91
Replace the door
interlock and
NO
restart the
diagnostic cycle
to check for
further alarms.
Replace the
wiring and restart
NO
the diagnostic
cycle to check for
further alarms.
circuit board, refer to page
E41
90
599 70 56-70

Hide quick links: