E69

E69: Washing heating element interrupted (version WD)

Tests to be performed:
Measure the heating
element value (Ω) across
terminals J6-2 ÷ J6-1 of the
wiring connector.
-see fig.4-
Is the value correct?
(26÷28Ω for 230V/1950W,
28÷31 for 240V/1950W)
YES
Replace the WD board and
restart the diagnostic cycle
to check for further alarms.
Fig.13
26÷28Ω 230V 1950W
26÷28Ω 230V 1950W
28÷31Ω 240V 1950W
28÷31Ω 240V 1950W
J11
J10
J9
J8
J16
Fig.4
03-2009 SOI/DT-mdm FCPD-dp Quality-fz
Measure the ohmic value
directly on the terminals of
NO
the heating element (detach
the connectors)
-see fig 13-
Is the value correct?
(26÷28Ω for 230V/1950W,
28÷31 for 240V/1950W)
Check/replace the wiring and
restart the diagnostic cycle to
check for further alarms.
J7
J5
J1
J2
U3
61/91
NO
YES
WD
board
If there are traces of burning on the
circuit board, refer to page
E69
Replace the heating
element and restart the
diagnostic cycle to check
for further alarms.
26÷28Ω 230V 1950W
28÷31Ω 240V 1950W
90