10.2.3 Operation of alarms during diagnostics
All alarms are enabled during the components diagnostics phase. Moving the selector to pass from one
control phase to the other, the appliance exits the alarm condition and performs the selected phase (if the
alarm does not occur again).
10.3 Notes about some alarms
Configuration alarms
E91: the error is indicated by the flashing of all the LEDs, E90 is displayed on the display, if
featured
E92: the error is indicated by the flashing of the LEDs placed over the buttons, E90 is displayed
on the display, if featured
E93: the error is indicated by the flashing of the phase/warning LEDs, E90 is displayed on the
display, if featured
EB1-EB2-EB3 alarms: in case of problems with the power supply, the machine remains in alarm
condition till the frequency or the power supply voltage returns to correct values or the appliance
is switched off. "EB0" alarm family is displayed and it is not possible to enter the diagnostics or to
use "alarm fast display" mode: the alarm complete can be read only when the abnormal situation
terminated.
E51- E52 alarms: during the diagnostics test all alarms are displayed: normally, moving the selector to
pass from one control phase to the other, the appliance exits the alarm condition and performs the
selected phase. This does not happen for the E51 alarms (motor power triac short-circuited) and E52
(no signal of motor tachimetric generator): the only possibility to exit from the alarm condition is to
switch the appliance off.
10.4 Rapid reading of alarm codes
The last alarm code can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
Press and hold down START/PAUSE and the option button nearest to the START/PAUSE button for at
least two seconds: the LEDs initially switch off, and then display the flashing sequence corresponding
to the alarm; if the display is featured, it will display the alarm code
The alarm sequence is displayed for the time in which the buttons are hold down
The reading system is the same as that indicated in paragraph. 10.2
During the time the alarm is displayed, the appliance continues to perform the cycle or, if it is in the
selection phase, it keeps in memory the options previously chosen.
10.5 Cancelling the last alarm
It is good practice to cancel the last alarm, after reading the alarm code to check whether the alarm re-
occurs during the diagnostics control after the reparation of the appliance.