Operation Of Alarms During Diagnostics; Notes About Some Alarms; Rapid Reading Of Alarm Codes; Cancelling The Last Alarm With Leds - Electrolux WASHING-MACHINES & WASHER-DRYERS Service Manual

Washing-machines & washer-dryers with electronic control ewm2000evo with sensors “full smd” display board
Table of Contents

Advertisement

13.2.3 Operation of alarms during diagnostics

All alarms are enabled during the components diagnostics phase. Moving the selector to pass from one
control phase to the other, the appliance exits the alarm condition and performs the selected phase (if the
alarm does not occur again).

13.3 Notes about some alarms

Configuration alarms
E91: the error is indicated by the flashing of all LEDs, E90 is displayed on the display, if featured.
E92: the error is indicated by the flashing of LEDs placed over the buttons, E90 is displayed on the
display, if featured.
E93: the error is indicated by the flashing of the phase/warning LEDs, E90 is displayed on the
display, if featured.
E95: the error is indicated by the flashing of all LEDs, E90 is displayed on the display, if featured.
EB1-EB2-EB3 alarms: in case of problems with the power supply, the machine remains in alarm
condition till the frequency or the power supply voltage returns to correct values or the appliance is
switched off. "EB0" alarm family is displayed and it is not possible to enter the diagnostics or to
use "alarm fast display" mode: the alarm complete can be read only when the abnormal situation
terminated.

13.4 Rapid reading of alarm codes

The last alarm code can be displayed even if the programme selector is not in the tenth position
(diagnostics) or if the appliance is in normal operating mode (e.g. during the execution of the washing
programme):
Press and hold down START/PAUSE and the option button nearest to the START/PAUSE button for at
least two seconds: the LEDs initially switch off, and then display the flashing sequence corresponding to
the alarm or the code on the display or a message on LCD.
The alarm sequence is displayed for the time in which the buttons are hold down
The reading system is the same as that indicated in paragraph. 13.2
During the time the alarm is displayed, the appliance continues to perform the cycle or, if it is in the
selection phase, it keeps in memory the options previously chosen.

13.5 Cancelling the last alarm with LEDs

It is good practice to cancel the last alarm, after reading the alarm code to check whether the alarm re-occurs
during the diagnostics control after the reparation of the appliance.
1. Select diagnostics mode and turn the
programme selector to the tenth position
(reading of alarm)
2. Press the START/PAUSE and its nearest option
button simultaneously.
3. Hold down the START/PAUSE and option
buttons (about 5 seconds).
SOI/DT 2005-01 dmm
57/67
599 36 82-59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ewm2000evo

Table of Contents