E32: The analogic pressure switch is giving an error during the
E32
(At the beginning of each cycle the appliance drain to empty the tub
and create a 0 level to verify the calibration of the analogic pressure switch)
Tests to be performed:
Drain the water from the tub.
Are pressure switch hose and air trap
system free? (You can disconnect the
hose and blow in it to check if the
system is free) fig. 2 and 8
YES
Check the draining system (filter,
drain pump, drain hose). Is the
machine draining correctly?
YES
Select a washing cycle. After few
minutes did the machine fill with water
and the motor is turning?
YES
Appliance is OK.
03-2009 SOI/DT-mdm FCPD-dp Quality-fz
calibration phase
Clean/change the hoses and/or air trap
system and repeat completely the
diagnostic cycle to check for further
NO
NO
Replace the analogic pressure switch
and run again the diagnostic cycle to
NO
Fig.2
31/91
alarms.
Clean the draining system.
YES
check for further alarms.
If there are traces of burning on the
circuit board, refer to page
E32
90
fig. 8
599 70 56-70

Hide quick links: