4036-307/308
Flatbed lamp inverter board removal
1.
Remove the flatbed cover with glass. See
2.
Remove the two screws (A) securing the flatbed optical CCD unit upper cover, and remove cover.
3.
Disconnect the cables (B).
4.
Remove the screw (C) holding the lamp inverter board to the flatbed CCD optical unit.
5.
Remove the lamp inverter board.
4-34
Service Manual
"Flatbed cover with glass removal" on page
A
B
C
4-28.