Upgrading Firmware Via Netlinx Studio - AMX MXD-1900L-PAN Operation/Reference Manual

19.4" modero x series® panoramic tabletop touch panel; 19.4" modero x series® panoramic wall touch panel
Hide thumbs Also See for MXD-1900L-PAN:
Table of Contents

Advertisement

Upgrading Firmware

Upgrading Firmware Via NetLinx Studio

The MXT-1900L-PAN and MXD-1900L-PAN use an Ethernet connection for programming, firmware
updates, and touch panel file transfer via NetLinx Studio. If you have access to the panel's network, you may
transfer files directly to the panel through NetLinx Studio.
Firmware upgrades cannot be made through an Ethernet-connected PC to the touch
panel, unless that PC is connected to the panel's network. Upgrades cannot be
made with NetLinx Studio through a USB connection to the panel from a PC. PC. For
more information on firmware transfers, please refer to the online help in NetLinx
Studio.
To upgrade firmware via NetLinx Studio:
1.
Launch NetLinx Studio and select Settings > Master Communication Settings from the Main menu to
open the Master Communication Settings dialog (FIG. 29).
FIG. 29
Master Communications Settings dialog
2.
Click the Communications Settings... button to open the Communications Settings dialog box (FIG. 30).
FIG. 30
Communications Settings dialog box
3.
Click on the NetLinx Master radio button from the Platform Selection section.
4.
Click on the Virtual Master radio box from the Transport Connection Option section to configure the PC
to communicate directly with a panel. Everything else, such as the Authentication, is greyed-out because
this connection is not going through the Master's UI.
28
MXD/T-1900L-PAN 19.4" Modero X Series® Panoramic Touch Panels

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mxt-1900l-pan

Table of Contents