Sfoc Calculations, Example - Man B&W S80ME-C7 Project Manual

Electronically controlled two-stroke engines
Table of Contents

Advertisement

MAN B&W Diesel A/S

SFOC calculations, example

Data at nominel MCR (L
Power 100%
Speed 100%
Nominal SFOC:
High efficiency turbocharger
M
power is selected as 85% of L
1
M
speed is selected as 90% of L
1
M
is in this example selected on the same
2
propeller curve as M
1
If the power of M
were selected as 75% of
2
L
= 17,460 kW and the corresponding speed is
1
86.3% of that in L
= 65.6 r/min
1
The savings in g/kWh compared to SFOC in L
Power in
Matching point
1
85% x 100% = 85.0%
M
= 85%
1
2
85% x 70% = 59.5%
of L
1
3
85% x 50% = 42.5%
4
75% x 100% = 75.0%
M
= 75%
2
5
75% x 70% = 52.5%
of L
1
6
75% x 50% = 37.5%
Fig. 2.10.01: Examples of SFOC for different specified MCR points for 6S80ME-C with fixed pitch propeller,
high efficiency turbocharger
S80ME-C
): 6S80ME-C
1
23,280 kW
76 r/min
167 g/kWh
= 19,788 kW
1
= 68.4 r/min
1
SFOC
saving
Data of specified MCR =
Power
Speed
SFOC found:
SFOC
g/kWh
+4
+3
+2
+1
0
-1
-2
-3
-4
6
-5
:
-6
1
-7
-8
-9
-10
1.9
-11
6.7
-12
3.2
-13
4.4
-14
-15
9.0
-16
4.9
30%
40%
M
19,788
68.4
165.1
Diagram a
Part Load SFOC curve
Nominal SFOC
3
M
2
4
2
5
50%
60%
70%
42.5
59.5
37.5
52.5
75
2.10
Page 1 of 2
M
1
2
17,400 kW
65.6 r/min
162.6 g/kWh
M
1
1
80%
90%
100%
110%
% of specified MCR
85
178 23 44-9.2
198 42 67-6.0