Alarms for UMS – Class and MAN Diesel requirements















































 Indicates that the sensor is required.
The sensors in the MAN Diesel column are included for Unattended Machinery Spaces (UMS), option: 4 75 27,
subject to class requirements and will be finally specified in the Guidance Values Automation for the specific
engine plant.
The sensor identification codes and functions are listed in Table 8.07.0.
The tables are liable to change without notice, and are subject to latest class requirements.
Select one of the alternatives
+
Alarm for high pressure, too
÷
Alarm for low pressure, too
Table 18.04.02b: Alarm functions for UMS
MAN B&W ME/MEC/MEGI/ME-B engines
 XC 23 A
 LS 235 AH
 LS 236 AH





 PT 840 AL
 PDS/PDT
 TE 8407 AL





 TE 8408 AH
 PT 843 I





 PT 842 AL
 TE 8422 AH





 PT 850 AL

 + 

 PT 8503 AL
 PT 8505 AL

 PS 8604 AL
 TE 8609 AH





 TE 860 AH





 LS 86 AH
Sensor and
function
Point of location
Hydraulic Power Supply
Automatic main lube oil filter, failure (Boll & Kirch)
Leakage oil from hydraulic pipes
Leakage oil from hydraulic power supply unit
Cooling water
Jacket cooling water inlet
Jacket cooling water across engine; to be calculated
8403 AL
in alarm system from sensor no. 8402 and 843
Jacket cooling water inlet
Jacket cooling water outlet, cylinder
Jacket cooling water outlet, common pipe
Cooling water inlet air cooler
Cooling water inlet air cooler/air cooler
Compressed air
Starting air inlet to main starting valve
Control air inlet and finished with engine
Air inlet to air cylinder for exhaust valve
Scavenge air
Scavenge air, auxiliary blower, failure (Only ME-B)
Scavenge air receiver
Scavenge air box – fire alarm, cylinder/cylinder
Water mist catcher – water level