EPSON PowerLite 5000 Service Manual
3.2.19 Removing the Inlet Unit
Prerequisite conditions: 3.2.3/3.2.4/3.2.8/3.2.13/3.2.17
Ground Wire Screw
Screws
Figure 3-33
1. Remove 2 inlet unit mounting screws and the ground wire screw.
2. Remove the cable guide cover.
3. Unplug the Fast-on tab cable (white wire) and the black wire from the filter board.
4. Pull up the inlet unit from the lower case.
Cable Guide Cover
Fast-on Tab Cable
(White Wire)
Figure 3-34
3-26