EPSON ELP-3500 Service Manual
3.2.18 Removing the Inlet Unit
Prerequisite: Complete the step explained in sections 3.2.1, 3.2.4, 3.2.5, 3.2.10, 3.2.11,
3.2.12, 3.2.13, and 3.2.15.
1. Remove the inlet unit mounting screw.
Screw:
2. Remove the cable wire from 4 clamps.
3. Pull up the board section of the inlet unit to remove the unit.
Screw
Figure 3-31.
+M3x8 F/Zn P-Tight: P/N 1021824
Mounting torque: 6.0 kg cm = 5.2 lb inch
Clamps
Figure 3-32.
3-25