Second System Option Code - DSC PC2525 Installation Manual

Version 1.1
Hide thumbs Also See for PC2525:
Table of Contents

Advertisement

[09] Second System Option Code

Zone Light 1: One Time Use Code Option
ON: One Time Use Code Enabled. Access Code 8 may be used to disarm and then later arm the system only
once. After the One Time Use Code is used to arm the system, it will be deleted and will not be able to
arm or disarm the system.
• OFF: One Time Use Code Disabled. Access Code 8 functions as a normal Access Code.
Zone Light 2: Master Code Options
ON: Master Code Not User-Changeable. The Master Code may not be changed by the user, and may only be
programmed in the Installer's Programming Mode.
• OFF: Master Code User-Changeable. The Master Code may be programmed by the user using the
[
][5][Master Code] command. The Master Code may also be programmed in the Installer's
Programming Mode.
Zone Light 3: Bypass and Access Code Options
ON: Access Code Required to Bypass Zones. After entering the [
Code must be entered before zones may be bypassed.
• OFF: Access Code Not Required to Bypass Zones. Enter the [
zones.
Zone Light 4: Auto-Arm Cancellation Options
• ON: Access Code Required to Cancel Auto-Arming. An Access Code must be entered to cancel the Auto-
Arm sequence during the 1-minute Auto-Arm Warning time.
OFF: Access Code not Required to Cancel Auto-Arming. Pressing any key during the 1-minute Auto-Arm
Warning time will cancel the Auto-Arming sequence.
Zone Light 5: Utility Output and Access Code Options
ON: Access Code Required to Activate Utility Output. After entering the [
Access Code must be entered before the Utility Output will be activated.
• OFF: Access Code Not Required to Activate Utility Output. Enter the [
the Utility Output.
Zone Light 6: Alarm Display Options
• ON: Alarms Displayed while Armed. Alarm conditions will be displayed on system keypads whether the
system is in the armed or disarmed state.
OFF: Alarms Displayed While Disarmed Only. Alarm conditions will be displayed only when the system is in
the disarmed state.
Zone Light 7: Bypass Status Display Options
ON: Show Bypass Status While Armed. The "Bypass" light will be ON while the system is armed to indicate
that there are bypassed zones on the system.
• OFF: Show Bypass Status While Disarmed Only. The "Bypass" light will be ON only while the system is
disarmed to indicate that there are bypassed zones on the system. When the system is armed, the
"Bypass" light will be shut OFF.
Zone Light 8: Bypassed Zone Display Options
ON: Show Bypassed Zones Always. The Zone Lights will be ON while the system is armed or disarmed to
indicate that there are bypassed zones.
• OFF: Show Bypassed Zones While Disarmed Only. The Zone Lights will only come ON while the system is
disarmed to indicate that there are bypassed zones. When the system is armed, the Zone Lights will be
shut OFF.
NOTE: If Alarms Displayed While Armed is enabled, bypassed zones will not be displayed while the
system is armed.
• Factory default setting
NOTE: If both Light 6 "Alarms Displayed While Armed" and Light 8 "Show Bypassed Zones Always" are enabled,
only alarms will be displayed while the system is armed.
16
][1] Bypass Zones Command, an Access
][1] Bypass Zones Command to bypass
][7] Utility Output Command, an
][7] Utility Output Command to activate

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents