Utility Output Command

∗ ∗ ∗ ∗ ∗
∗ ∗ ∗ ∗ ∗
[
]+[7] or [

]+[7]+[Access Code]

The Programmable Output (PGM terminal) can be programmed for activation by a keypad command. This output
can be used to operate other devices such as door openers, special lighting, door strikes or to reset smoke
detectors. Refer to Programming Section [09] Light 5. Depending on the option selected, the [
may require that an Access Code be entered to activate the Utility Output.
When the correct command is entered, the keypad sounder and the PGM output will operate for 5 seconds.
Installer's Programming Command
∗ ∗ ∗ ∗ ∗
[

]+[8]+[Installer's Code]

The PC2525 is completely programmed from the keypad by using commands in the [
commands are described in detail in the programming section of this manual. The default Installer's Code is
[2525].
At-Home Arming
∗ ∗ ∗ ∗ ∗
[
]+[9]+[Access Code]
Entering [
][9] before the arming code will arm the panel without the entry delay on delay zones. Also "Home-
away" zones are automatically bypassed. When armed using the [
remind the user that the system is armed without the entry delay. This command allows the user to remain at
home and have an instant alarm on the entry doors.

Keypad Zones [F], [A], [P]

There are three zones which can be activated with single key entries on the keypad. For the [F], [A] and [P] keys
to be functional for transmission, they must be enabled by the installer by entering the Alarm and Restoral Codes
in Programming Section [38].
[F]ire Key
Pressing the [F] key and holding it for 2 seconds will initiate a local pulsing alarm and, if
programmed, will transmit the alarm to the monitoring station. A Fire alarm may also be
generated by pressing the [1] and [3] keys together and holding them down for 2 seconds. The
keypad will sound a series of short beeps once the panel has accepted the alarm. The [F] key
may be disabled in Programming Section [10].
[A]uxiliary Key Pressing the [A] key and holding it for 2 seconds will, if programmed, transmit an Auxiliary alarm
to the monitoring station. An Auxiliary alarm may also be generated by pressing the [4] and [6]
keys together and holding them down for 2 seconds. There is no local alarm and no keypad
lights will come ON when this key function is activated. The keypad will sound a series of short
beeps upon successful completion of the transmission to the monitoring station.
[P]anic Key
Pressing the [P] key and holding it for 2 seconds will, if programmed, send a transmission to the
monitoring station. A Panic alarm may also be generated by pressing the [
together and holding them down for 2 seconds. The alarm signal can be programmed to be
audible or silent; see Programming Section [10] Third System Option Code. If programmed as
audible, the local bell / siren will sound steadily.
Keypad audible annunciation for the [P] key is programmable in Programming Section [10] for audible (3 beeps)
or silent (no buzzer feedback). If programmed for audible, the buzzer will sound once the key input is accepted.
10
][8] section. These
][9] command, the "Armed" light will flash to
][7] command
] and [#] keys