Fourth System Option Code; Bypass Mask For Zones 1 - 8; Bypass Mask For Access Codes 1 - 8 - DSC PC2525 Installation Manual

Version 1.1
Hide thumbs Also See for PC2525:
Table of Contents

Advertisement

[11] Fourth System Option Code

Zone Light 1: Bell Pulse Options
ON: Bell Pulses for All Alarms. The bell or siren will pulse for all types of audible alarms.
• OFF: Bell Pulses for Fire Alarm Only. The bell or siren will pulse for Fire and [F] Key alarms. For all other
audible alarms, the bell or siren will sound a steady alarm.
Zone Light 2: Bell Squawk on Exit Delay Options
ON: Bell Squawk on Exit Delay. The Bell output will pulse during the Exit Delay Time.
• OFF: No Bell Squawk on Exit Delay.
Zone Light 3: Bell Squawk on Entry Delay Options
ON: Bell Squawk on Entry Delay. The Bell output will pulse during the Entry Delay Time.
• OFF: No Bell Squawk on Entry Delay.
Zone Light 4: Audible Exit Fault Enabled / Disabled
• ON: Audible Exit Fault Enabled. If a Delay Zone is left open at the end of the Exit Delay, the Entry Delay will
begin immediately and the bell or siren will sound a steady alarm. This feature is designed to
immediately alert the user that their system has been armed incorrectly.
OFF: Audible Exit Fault Disabled. If a Delay Zone is left open at the end of the Exit Delay, the Entry Delay will
begin immediately. If the system is not disarmed before the end of the Entry Delay, an alarm will be
generated.
Zone Light 5: Exit Delay Urgency Tone Option
• ON: Audible Exit Delay with Urgency. The Keypad will sound a pulsing tone during the Exit Delay. During the
last 10 seconds of the Exit Delay, the keypad will sound a faster pulsing tone to warn that the Exit Delay is
about to expire.
OFF: Standard Exit Delay. The Keypad will not sound during the Exit Delay time.
Zone Light 6: Entry Delay Urgency Tone Option
• ON: Urgency Applied to Entry Delay. The Keypad will sound a steady tone during the Entry Delay. During the
last 10 seconds of the Entry Delay, the keypad will sound a pulsing tone to warn that the Entry Delay is
about to expire.
OFF: Standard Entry Delay. The Keypad will sound a steady tone throughout the Entry Delay time.
Zone Light 7: Telephone Line Monitor Disabled / Enabled
ON: Telephone Line Monitor Disabled. The TLM function will be shut off and telephone line troubles will not
be indicated by the system.
• OFF: Telephone Line Monitor Enabled. The TLM function will be active and the system will report telephone
line troubles by indicating Trouble Condition 4 when using the [
Zone Light 8: Telephone Line Monitor Trouble Options
ON: TLM Generates Trouble Condition. A Telephone Line Monitor Trouble will generate a trouble indication;
the "Trouble" light will come ON and the keypad sounder will beep until the [
Conditions Command is entered.
• OFF: TLM Generates Alarm When Armed. When the system is disarmed, a Telephone Line Monitor Trouble will
generate a trouble indication as described above. If the system is armed, a Telephone Line Monitor
trouble will generate an audible alarm on the bell or siren.
• Factory default setting

[12] Bypass Mask for Zones 1 - 8

This Section determines which zones may be bypassed using the [
Light is ON, the zone can be bypassed; if the Zone Light is OFF, the zone cannot be bypassed. Note that fire
zones cannot be bypassed.

[13] Bypass Mask for Access Codes 1 - 8

This Section determines which Access Codes may be used to bypass zones using the [
Command. If the Zone Light is ON, the Access Code may be used to bypass zones; if the Zone Light is OFF, the
Access Code cannot be used to bypass zones.
18
][2] View Trouble Conditions Command.
][2] View Trouble
][1] Bypass Zones Command. If the Zone
][1] Bypass Zones

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents