Master Code]+[2]; Auto-Arm On/Off; Master Code]+[5]; System Test - DSC PC2525 Installation Manual

Version 1.1
Hide thumbs Also See for PC2525:
Table of Contents

Advertisement

Setting the Clock
∗ ∗ ∗ ∗ ∗
[
]+[6]+[Master Code]+[1]
The System Clock is a 24-hour clock. Hours and minutes must be entered as 2-digit numbers.
• HH, hours: 00 to 23 MM, minutes: 00 to 59
8:05 AM would be entered as 0805; 1:30 PM would be entered as 1330
Setting the system clock tells the system the time of day. If the system is without power, (AC and battery), it
cannot continue to keep time. When the panel is powered up, the system clock must be reset. If the time needs
to be reset, then a Trouble Condition 8 will be indicated on the keypad (refer to [
Trouble Condition 8 will not be generated if the Auto-Arm and Auto-Test times are not programmed with valid
times (9999 in these positions disables these features).

Set Auto-Arm Time

∗ ∗ ∗ ∗ ∗
[

]+[6]+[Master Code]+[2]

The PC2525 can be programmed to arm at the same time each day. To set the Auto-Arm time, enter
[
][6][Master Code][2] then enter the hours and minutes as described at the beginning of this section.
At the selected Auto-Arm time, the bell will sound one short burst every 10 seconds for a 1-minute period if
Section [10] Zone Light 7 is OFF. The keypad will also sound for 1 minute. At the end of the 1-minute warning
period, the system will be fully armed and there will be no exit delay at this time.
Auto-Arming may be cancelled by pressing any key on the keypad during the 1-minute warning period. When a
key is pressed, the warning will be silenced and Auto-Arming will be cancelled. Auto-Arming will be attempted at
the same time the next day. During the 1-minute warning period, keyswitch arming or arming using the Quick-
Arm command will cancel the Auto-Arm process and will initiate the exit delay before arming the system.
If Programming Section [9] Zone Light 4 is ON, then an Access Code will be required to cancel Auto-Arming.
When an Access Code is entered during the 1-minute warning period, the warning will be silenced and Auto-
Arming will be cancelled. Auto-Arming will be attempted at the same time the next day.
Quick-Arm
∗ ∗ ∗ ∗ ∗
ON/OFF [
]+[6]+[Master Code]+[4]
Pressing [4] while in the User Function Command mode will Enable (3 beeps) or Disable (one long beep) the
Quick-Arm feature. With this feature enabled, the panel can be armed by simply entering [
Auto-Arm
∗ ∗ ∗ ∗ ∗
ON/OFF [

]+[6]+[Master Code]+[5]

Pressing [5] while in the User Function Command mode will enable (3 beeps) or disable (one long beep) the
Auto-Arm feature. With this feature enabled, the panel will automatically arm at the same time each day. The
Auto-Arm time is programmed with the [

System Test

∗ ∗ ∗ ∗ ∗
[

]+[6]+[Master Code]+[8]

Pressing [8] while in the User Function Command mode will sound the bell/siren, the keypad sounder and turn on
all the keypad lights for 2 seconds. If a System Test Code is programmed in Section [39], it will be transmitted at
the same time.

User Call-up

∗ ∗ ∗ ∗ ∗
[

]+[6]+[Master Code]+[9]

Enable the User Call-up Function in Programming Section [70], Zone Light 2. When User Call-up is activated, the
system will call the downloading computer. The downloading computer must be waiting for the system to call
before downloading can be performed.
Installer's Test
∗ ∗ ∗ ∗ ∗
ON/OFF [

]+[6]+[Master Code]+[0]

Pressing the [0] key while in the User Function Command mode will enable or disable the Installer's Test function.
This feature allows final testing of the system. When enabled, the bell/siren will operate for 2 seconds each time a
zone is put into alarm or when the [F] key is pressed. The bell/siren will also sound for 2 seconds when the [P]
key is pressed and the [P] key is programmed for audible operation. As the [A] key generates a silent alarm, the
bell/siren will not sound if this key is pressed.
Each zone should be tripped individually to avoid confusion about which zone originates the alarm. To exit the
Installer's Test mode, arm then disarm the panel. NOTE: The communicator will transmit all alarms and restorals.
Disable the communicator if this is not desired (Section [46], Zone Light 1).
][6][Master Code][2] command.
][2] System Trouble Display).
][0].