[06] Programmable Output Options

The PGM terminal can be programmed to operate in response to various system operations. The output pulse
connects the PGM terminal to the negative power rail. The switching transistor used for this purpose can sink up
to 55 mA.
[00] 2-Wire Smoke Detectors
When programmed as [00], the PGM output will be programmed for use with 2-wire smoke detectors. Refer to
the Hook-Up Diagram for instructions on connecting 2-wire smoke detectors. The 2-wire smoke detector circuit
will function in the same manner as a Type 8 Delayed Fire zone; refer to Section [01] for more information.
[01] Utility Output, no Access Code
When activated by entering the [
buzzer will sound.
[02] 5-Second Reset Pulse
When this option is selected, the PGM output is normally low. That is, it is just the reverse of all other options
which are normally high and go low when activated. This option is normally used as the negative return for
power to 4-wire smoke detectors (positive comes from the AUX + terminal). To activate this output (to reset
smoke detectors), enter the [
power from the devices connected. The keypad buzzer will sound for the 5-second period. Refer to the
Hook-up Diagram at the back of this manual for instructions on connecting smoke detectors.
[03] Strobe Output (Latched Alarm)
The PGM switches to ground on an alarm and remains low until the panel is disarmed. It can be used to
indicate that an alarm has occurred before entering the premises.
[04] System Status (Armed / Disarmed)
The PGM output switches to and remains at ground as long as the panel is armed. The output goes high
(open) while the panel is disarmed.
[05] Keypad Buzzer Follow Mode
The PGM output will go low when the keypad buzzer is activated by the "24 Hour Buzzer Zone", "Door
Chime", "Entry Delay" and "Auto-Arm Alert" functions. The PGM output will go low for as long as the keypad
buzzer is active. The PGM output will also be activated for the duration of the Exit Delay if an Audible Exit
Delay is selected in Section [11] Zone Light 5.
[06] Courtesy Pulse (Follow Entry and Exit Delays)
This option provides an output which follows the entry and exit times. It can be used to turn on a courtesy
light near the exit door for the duration of the entry / exit times.
[07] Entry Delay Follow Mode
This option provides an output which follows the Entry Delay only.
[08] Exit Delay Follow Mode
This option provides an output which follows the Exit Delay only.
[09] LINKS1000 Support Mode
This option configures the PGM terminal for operation with the LINKS1000 Cellular Alarm Communicator.
[10] Ground Start Pulse
This option provides a 2-second output pulse before dialing begins to obtain the dial tone on Ground Start
telephone equipment
[11] TLM and Alarm
The PGM output switches to ground if the system detects a TLM fault when there is an alarm condition. The
output follows the time programmed for the Bell Timeout.
[12] Second Line Slave
The PGM output switches to ground after there have been four unsuccessful communication attempts. The
output will remain switched until the system has hung up the telephone line. This feature may be used to
activate an additional communicator for back-up communications.
[13] Failure to Communicate
The PGM output switches to ground if the system fails to communicate after 8 attempts to each phone number
that will be tried according to the communicator call direction options. The output remains low until a
successful communication takes place or until Trouble Condition 5 is cleared from the keypad. This option can
be used to tie two systems together so that if one fails to communicate, the other system will report the failure.
[14] Kissoff Output
The PGM output switches to ground after the kissoff signal has been received to complete a successful
communication to the central station. The output will switch to ground for 2 seconds.
[15] Remote Operation
This option alows the PGM output to be activated on command through the DLS-1 downloading software
package. DLS-1 v5.3 or later software supports this option.
14
][7] command, the PGM output will go low for 5 seconds and the keypad
][7] command. The PGM terminal will go high (open circuit), and thus remove

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents