Adjustment > Creating Reference Data
8) Choose WHITE BALANCE ABS on the SETUP MENU
screen.
9) Repeat steps 2)-5).
10) Click the RETURN button on SETUP MENU screen.
11) The ALL SETUP FINISH dialog will appear: Click the
OK button to complete the creation of reference data.
Note:
Neither Matrix, White Balance nor White Balance Abs in
SETUP MENU can be executed independently. Be sure to
execute all items at the same time.
If you click the RETURN button on the SETUP MENU
screen with an unfinished item, the EXECUTE OTHER
ITEMS dialog will appear. Click the OK button in
EXECUTE OTHER ITEMS dialog, and then execute the
unfinished items.
EXECUTE OTHER ITEMS dialog
CONTINUE
EXECUTE OTHER ITEMS.
OK
6 - 11
SETUP MENU screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SETUP MENU
Matrix
White Balance
White Balance Abs
9
EXECUTE
RETURN
ALL SETUP FINISH dialog
FINISHED
ALL SETUP FINISHED.
11
OK
8
10